A comparison between the diagnostic efficacy of 99mTc-MDP, 99mTc-DPD and 99mTc-HDP for the detection of bone metastases
European Journal of Nuclear Medicine · 1983-03 · 8 (3)
DOI: 10.1007/bf00256735 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Nuclear Medicine, 1983-03. Verfasst von E K Pauwels und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Diphosphonates, Organotechnetium Compounds, Technetium. Die Arbeit wurde bisher 38-mal zitiert (Crossref).
Abstract (Originalsprache)
We have investigated the clinical efficacy for the detection of bone metastases of two recently marketed bone-seeking radiopharmaceuticals, HDP and DPD, compared with traditionally used MDP. Twenty patients received 15 mCi 99mTc-MDP; after assessment ten of these patients later received 15 mCi 99mTc-DPD and ten other patients of this group were injected with 15 mCi 99mTc-HDP. Scintigraphy took place 3 h after tracer injection. Quantitative analysis included the calculation of normal bone to soft tissue ratios, lesion to soft tissue ratios and lesion to normal bone ratios for all three radiopharmaceuticals. Visual inspection of the scintiphotos revealed the same number of bone lesions at the same localisations. Statistical evaluation of our quantitative data showed that the lesion to normal bone ratio was significantly higher for MDP than for DPD. No further significant differences in the uptake in normal bone or in the metastatic lesions were found between all three radiopharmaceuticals. It is concluded that the new bone-seeking agents DPD and HDP do not possess clinical advantages over MDP for the detection of skeletal metastases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Zitieren
APA
Pauwels, E. K., Blom, J., Camps, J. A., Hermans, J., & Rijke, A. M. (1983). A comparison between the diagnostic efficacy of 99mTc-MDP, 99mTc-DPD and 99mTc-HDP for the detection of bone metastases. European Journal of Nuclear Medicine, 8(3). https://doi.org/10.1007/bf00256735
Vancouver
Pauwels EK, Blom J, Camps JA, Hermans J, Rijke AM. A comparison between the diagnostic efficacy of 99mTc-MDP, 99mTc-DPD and 99mTc-HDP for the detection of bone metastases. European Journal of Nuclear Medicine. 1983;8(3). doi:10.1007/bf00256735
BibTeX
@article{Pauwels1983,
author = {Pauwels, E K and Blom, J and Camps, J A and Hermans, J and Rijke, A M},
title = {A comparison between the diagnostic efficacy of 99mTc-MDP, 99mTc-DPD and 99mTc-HDP for the detection of bone metastases},
journal = {European Journal of Nuclear Medicine},
year = {1983},
volume = {8},
number = {3},
doi = {10.1007/bf00256735}
}