Comparison of two different electrosurgical devices in reduction mammoplasty: Monopolar electrocautery versus plasmakinetic cautery
World Journal of Surgery · 2024
DOI: 10.1002/wjs.12259 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift World Journal of Surgery, 2024. Verfasst von Tugba Gun Koplay. Beteiligte Einrichtung: Department of Plastic Reconstructive and Aesthetic Surgery, University of Health Sciences, Konya City Hospital, Konya, Turkey. Hauptthemen laut MEDLINE: Electrocoagulation, Mammaplasty, Cautery. Die Arbeit nennt 12 Literaturangaben.
Abstract (Originalsprache)
Background
Many devices are used for dissection and hemostasis during reduction mammoplasty. While one of the most common methods is monopolar electrocautery, tissue damage due to thermal spread remains a controversial topic. New devices have been designed to minimize this effect. In this study, plasmakinetic cautery was hypothesized to reduce sensation loss, drainage, and wound‐healing problems in reduction mammoplasty because it is less harmful to the surrounding tissues.
Methods
Sixty‐eight patients were evaluated in a matched pair design, with random (blinded) assignment of 34 patients with conventional monopolar electrocautery (Group A) and 34 patients with plasmakinetic cautery (group B). Postoperative drainage volume, drain duration, nipple‐areolar complex (NAC) sensation, and complications (dehiscence, seroma, ischemia, and nipple circulatory problems) were compared by the researcher, who was blinded to the device used for the patient.
Results
The groups were comparable in terms of age, body mass index (BMI), comorbidities, and medications ( p > 0.05). The mean age of the patients were 38.50 ± 9.14 years in group A and 37.54 ± 8.17 in group B. The mean BMI was 25.19 ± 3.22 kg/m 2 in group A and 25.65 ± 2.96 kg/m 2 in group B. No differences were detected between the groups in terms of drain duration time, NAC sensation, or complications, but the drainage volume was statistically lower with plasmakinetic cautery ( p < 0.05).
Conclusion
The study findings indicate that the main advantage of plasmakinetic cautery in reduction mammoplasty was a decrease in drainage volume when compared with monopolar electrocautery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Plastic Reconstructive and Aesthetic Surgery, University of Health Sciences, Konya City Hospital, Konya, Turkey.
ORCID-Profile: Tugba Gun Koplay
Zitieren
APA
Koplay, T. G. (2024). Comparison of two different electrosurgical devices in reduction mammoplasty: Monopolar electrocautery versus plasmakinetic cautery. World Journal of Surgery. https://doi.org/10.1002/wjs.12259
Vancouver
Koplay TG. Comparison of two different electrosurgical devices in reduction mammoplasty: Monopolar electrocautery versus plasmakinetic cautery. World Journal of Surgery. 2024. doi:10.1002/wjs.12259
BibTeX
@article{Koplay2024,
author = {Koplay, Tugba Gun},
title = {Comparison of two different electrosurgical devices in reduction mammoplasty: Monopolar electrocautery versus plasmakinetic cautery},
journal = {World Journal of Surgery},
year = {2024},
doi = {10.1002/wjs.12259}
}
EUVIMED