EUVIMEDEUVIMED entdecken
Open Access

Ultrasensitive Fluorimetric Detection of Trace Se(IV) as 4,5‐Benzopiazselenol on Nonpolar Adsorbents

Vladimir Losev, Anastasya Orobyeva, Svetlana Didukh-Shadrina, Sergey Metelitsa, Elena Borodina, Vyacheslav Cherkashin, Urana Ondar

Water Environment Research · 2026-07 · 98 (7)

DOI: 10.1002/wer.70486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Water Environment Research, online erschienen am 14.07.2026. Verfasst von Vladimir Losev und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Science and Innovation, Siberian Federal University, Krasnoyarsk, Russian Federation. Hauptthemen laut MEDLINE: Water Pollutants, Chemical, Fluorometry. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Ministry of Science and Higher Education of the Russian Federation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A method for separating Se(IV) from Se(VI) has been proposed. The method is based on the formation of fluorescent 4,5‐benzopiazselenol (a complex of Se(IV) with 2,3‐diaminonaphthalene), which was quantitatively extracted in dynamic mode from aqueous solutions using glass preconcentrating cartridges filled with nonpolar adsorbents: SiO 2 ‐C8, SiO 2 ‐C16, SiO 2 ‐C18, and SiO 2 ‐HPh. The increase in the fluorescence intensity of the adsorbent in the preconcentrating cartridge with increasing concentration of 4,5‐benzopiazselenol on its surface was used to develop a method for the solid‐phase extraction (SPE)‐fluorimetric determination of Se(IV) with a detection limit of 2 ng per 0.025 g of SiO 2 ‐С16 adsorbent. When using 10 mL of solution, the detection limit was 0.2 ng mL −1 (0.2 μg L −1 ), and when using 100 mL of solution, it was 0.02 ng mL −1 (0.02 μg L −1 ). The linearity of the calibration graph was maintained up to 2 μg per 0.025 g when using the SiO 2 ‐C16 adsorbent. Se(VI) did not form a complex with diaminonaphthalene and was not extracted by nonpolar adsorbents. Se(VI) passing through the preconcentrating cartridge can be determined in the effluent by ICP‐MS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Water Pollutants, ChemicalFluorometryAdsorptionSolid Phase ExtractionLimit of DetectionSilicon Dioxide

Stichwörter der Autor:innen

4,5‐benzopiazselenolICP‐MS determinationfluorescent determinationnonpolar adsorbentsolid‐phase extractionspeciation of inorganic selenium

Substanzen

Water Pollutants, ChemicalSilicon Dioxide

Autor:innen und Institutionen

  • Department of Science and Innovation, Siberian Federal University, Krasnoyarsk, Russian Federation.
  • Department of Chemistry, Tuvan State University, Kyzyl, Russian Federation.

Förderung

  • Ministry of Science and Higher Education of the Russian Federation

Zitieren

APA

Losev, V., Orobyeva, A., Didukh-Shadrina, S., Metelitsa, S., Borodina, E., Cherkashin, V., & Ondar, U. (2026). Ultrasensitive Fluorimetric Detection of Trace Se(IV) as 4,5‐Benzopiazselenol on Nonpolar Adsorbents. Water Environment Research, 98(7). https://doi.org/10.1002/wer.70486

Vancouver

Losev V, Orobyeva A, Didukh-Shadrina S, Metelitsa S, Borodina E, Cherkashin V, et al. Ultrasensitive Fluorimetric Detection of Trace Se(IV) as 4,5‐Benzopiazselenol on Nonpolar Adsorbents. Water Environment Research. 2026;98(7). doi:10.1002/wer.70486

BibTeX
@article{Losev2026,
  author = {Losev, Vladimir and Orobyeva, Anastasya and Didukh-Shadrina, Svetlana and Metelitsa, Sergey and Borodina, Elena and Cherkashin, Vyacheslav and Ondar, Urana},
  title = {Ultrasensitive Fluorimetric Detection of Trace Se(IV) as 4,5‐Benzopiazselenol on Nonpolar Adsorbents},
  journal = {Water Environment Research},
  year = {2026},
  volume = {98},
  number = {7},
  doi = {10.1002/wer.70486}
}
Kostenlos starten →