Overcoming strong retention barriers of A- and V-series nerve agents on silica sorbents

Gyanesh Mishra, Pranav Gupta, Ajay Purohit, Raghavender Goud, Deepak Pardasani

Journal of Chromatography A · 2024

DOI: 10.1016/j.chroma.2024.465385 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chromatography A, 2024. Verfasst von Gyanesh Mishra und 4 weiteren Autor:innen. Beteiligte Einrichtung: Vertox Laboratory, Defence Research and Development Establishment, Gwalior, India. Hauptthemen laut MEDLINE: Silicon Dioxide, Solid Phase Extraction, Nerve Agents, Gas Chromatography-Mass Spectrometry. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The present study explores the potential of silica solid phase extraction for gas chromatography mass spectrometric analyses of A- and V-series nerve agents. Owing to the presence of basic amidine and amine moieties, these analyte undergo strong ionic interactions with inherently acidic silica surfaces, producing poor recoveries. Subtle optimizations in the elution composition empowered the analytes to overcome the retention barriers from sorbent surfaces. Acetone containing 10 % (v/v) NH4OH effectively minimized strong analyte-sorbent interactions allowing good to excellent recoveries. Recoveries for A-series agents ranged from 88 to 96 %. VX, which is reported to be poorly recoverable from such sorbent matrices offered best data so far, reaching up to 74 % under optimized conditions. The method detection limits for the selected analytes in mass spectrometric analysis ranged from 47 to 171 ng/ml. Strong affinities of analytes towards silica sorbent were further exploited to expand the scope of analysis and establish the method's efficacy for a wide range of organic matrices. The applicability of the method to the real world applications was also validated in blind spiking exercises in diverse organic liquid samples received in 48th, 50th and 52nd proficiency tests conducted by the Organization for the Prohibition of Chemical Weapons (OPCW).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Silicon DioxideSolid Phase ExtractionNerve AgentsGas Chromatography-Mass SpectrometryLimit of DetectionAdsorptionOrganothiophosphorus CompoundsAcetone

Stichwörter der Autor:innen

Chemical Weapons ConventionNerve AgentsNovichoksSilica Solid Phase ExtractionVX

Substanzen

Silicon DioxideNerve AgentsOrganothiophosphorus CompoundsAcetoneVX-agent

Autor:innen und Institutionen

  • Vertox Laboratory, Defence Research and Development Establishment, Gwalior, India.
  • Vertox Laboratory, Defence Research and Development Establishment, Gwalior, India. Electronic address: dkpardasani.drde@gov.in.

Zitieren

APA

Mishra, G., Gupta, P., Purohit, A., Goud, R., & Pardasani, D. (2024). Overcoming strong retention barriers of A- and V-series nerve agents on silica sorbents. Journal of Chromatography A. https://doi.org/10.1016/j.chroma.2024.465385

Vancouver

Mishra G, Gupta P, Purohit A, Goud R, Pardasani D. Overcoming strong retention barriers of A- and V-series nerve agents on silica sorbents. Journal of Chromatography A. 2024. doi:10.1016/j.chroma.2024.465385

BibTeX
@article{Mishra2024,
  author = {Mishra, Gyanesh and Gupta, Pranav and Purohit, Ajay and Goud, Raghavender and Pardasani, Deepak},
  title = {Overcoming strong retention barriers of A- and V-series nerve agents on silica sorbents},
  journal = {Journal of Chromatography A},
  year = {2024},
  doi = {10.1016/j.chroma.2024.465385}
}
Kostenlos starten →