EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas

Sait Sendag iD, Henrik Wagner iD, Ali Osman Turgut iD, Davut Koca iD, Gerhard Schuler iD, Axel Wehrend iD

Veterinary Medicine and Science · 2025

DOI: 10.1002/vms3.70558 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Medicine and Science, 2025. Verfasst von Sait Sendag und 5 weiteren Autor:innen. Beteiligte Einrichtung: Deparment of Obstetrics and Gynecology, Van Yuzuncu Yil University, Van, Türkiye. Hauptthemen laut MEDLINE: Camelids, New World, Anti-Mullerian Hormone. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Anti‐Müllerian hormone (AMH) has become an important hormonal parameter for the detection of gonadal tissue and for the diagnosis of gonadal functions and pathologies. To our knowledge, there is currently no homologous test for AMH measurements in South American camelids (SACs). Therefore, the objective of the present study was to determine serum AMH concentrations in postpubertal male alpacas and, for the first time, in llamas, using the Elecsys AMH assay kit that has not previously been tested in these species. To obtain indications of the specificity of this method in SAC, measurements were carried out in male gelding in which concentrations below the detection limit were to be expected.

Methods

In this context, 37 blood samples collected by jugular venipuncture from 21 alpacas and 16 llamas were used. The obtained blood was centrifuged at 3000 g for 20 min, and the serum was stored in Eppendorf tubes at −20°C until AMH concentrations were measurement. The measurement of AMH levels was conducted in a commercial diagnostic laboratory (Laboklin, Bad Kissingen, Germany) using the electrochemiluminescence immunoassay kit Elecsys AMH run on the fully automated Cobas e 601 analyser (Roche Diagnostics Deutschland GmbH, Mannheim). The AMH test had a minimum detection limit of 0.01 ng/mL and a maximum detection limit of 23 ng/mL. The intra‐assay coefficient of variation is between 2.7% and 3.3%.

Results

Blood serum AMH levels ranged between 4.10 and 22 ng/mL (median: 9.80 ng/mL) and 1.79 and 10.05 ng/mL (median: 4.00) in intact alpacas (age: 6.30 ± 2.71 years; n = 10) and llamas (age: 5.50 ± 4.34; n = 8), respectively, and were significantly different between samples obtained from the two species ( p < 0.05). Correlation analyses regarding an age dependence of AMH concentrations yielded negative correlation coefficients for both species but non‐significant p values (alpaca: r = −0.165, p = 0.649; llama: r = −0.547, p = 0.160). In alpaca ( n = 11) and llama geldings ( n = 8), blood serum AMH levels were below 0.01 ng/mL ( p < 0.001). These results prove that the antibodies used in the Elecsys AMH assay significantly and specifically cross‐react with SAC AMH.

Conclusions

In gelding llamas and alpacas, AMH concentrations were below the limit of detection (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Camelids, New WorldAnti-Mullerian HormoneAnimalsMaleSensitivity and SpecificityImmunoassay

Stichwörter der Autor:innen

AMH assaySouth American camelidsanti‐Müllerian hormone

Substanzen

Anti-Mullerian Hormone

Autor:innen und Institutionen

  • Deparment of Obstetrics and Gynecology, Van Yuzuncu Yil University, Van, Türkiye.
  • Veterinary Clinic for Reproductive Medicine and Neonatology, Justus-Liebig-University, Giessen, Germany.
  • Department of Animal Science, Faculty of Veterinary Medicine, Siirt University, Siirt, Türkiye.

ORCID-Profile: Sait Sendag, Henrik Wagner, Ali Osman Turgut, Davut Koca, Gerhard Schuler, Axel Wehrend

Zitieren

APA

Sendag, S., Wagner, H., Turgut, A. O., Koca, D., Schuler, G., & Wehrend, A. (2025). The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas. Veterinary Medicine and Science. https://doi.org/10.1002/vms3.70558

Vancouver

Sendag S, Wagner H, Turgut AO, Koca D, Schuler G, Wehrend A. The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas. Veterinary Medicine and Science. 2025. doi:10.1002/vms3.70558

BibTeX
@article{Sendag2025,
  author = {Sendag, Sait and Wagner, Henrik and Turgut, Ali Osman and Koca, Davut and Schuler, Gerhard and Wehrend, Axel},
  title = {The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas},
  journal = {Veterinary Medicine and Science},
  year = {2025},
  doi = {10.1002/vms3.70558}
}
Kostenlos starten →