Static and dynamic responses to hyperoxia of normal placenta across gestation with T2 *‐weighted MRI sequences
Ultrasound in Obstetrics & Gynecology · 2024
DOI: 10.1002/uog.27609 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasound in Obstetrics & Gynecology, 2024. Verfasst von R Bartin und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fetal Medicine, Surgery and Imaging, Hôpital Universitaire Necker-Enfants Malades, AP-HP, Paris, France. Hauptthemen laut MEDLINE: Placenta, Hyperoxia, Magnetic Resonance Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 33 Literaturangaben.
Abstract (Originalsprache)
Objectives
T2*‐weighted magnetic resonance imaging (MRI) sequences have been identified as non‐invasive tools with which to study placental oxygenation in vivo . This study aimed to use these to investigate both static and dynamic responses to hyperoxia of the normal placenta across gestation.
Methods
We conducted a single‐center prospective study including 52 uncomplicated pregnancies. Two T2*‐weighted sequences (T2* relaxometry) were performed, one before and one after maternal hyperoxia. The distribution of placental T2* values was modeled by fitting a gamma probability density function ( T2* ) , describing the structure of the histogram using the mean T2* value, the shape parameter (α) and the rate (β). A dynamic acquisition (blood‐oxygen‐level‐dependent (BOLD) MRI) was also performed before and during maternal oxygen supply, until placental oxygen saturation had been achieved. The signal change over time was modeled using a sigmoid function, to determine the intensity of enhancement (ΔBOLD (% with respect to baseline)), a temporal variation coefficient (λ (min –1 ), controlling the slope of the curve) and the maximum steepness (Vmax (% of placental enhancement/min)).
Results
The histogram analysis of the T2* values in normoxia showed a whole‐placenta variation, with a decreasing linear trend in the mean T2* value (Pearson's correlation coefficient ( R ) = −0.83 (95% CI, −0.9 to −0.71), P < 0.001), along with an increasingly peaked and narrower distribution of T2* values with advancing gestation. After maternal hyperoxia, the mean T2* ratios (mean T2* hyperoxia /mean T2* baseline ) were positively correlated with gestational age, while the other histogram parameters remained stable, suggesting a translation of the histogram towards higher values with a similar appearance after maternal hyperoxia. ΔBOLD showed a non‐linear increase across gestation. Conversely, λ showed an inverted trend across gestation, with a weaker correlation ( R = −0.33 (95% CI, −0.58 to −0.02), P = 0.04, R 2 = 0.1). As a combination of ΔBOLD and λ, the changes in Vmax throughout gestation were influenced mainly by the changes in ΔBOLD and showed a positive non‐linear correlation with gestational age.
Conclusions
Our results suggest that the decrease in the T2* placental signal as gestation progresses does not reflect placental dysfunction. The BOLD dynamic signal change is representative of a free‐diffusion model of oxygenation and highlights the increasing differences in oxygen saturation between mother and fetus as gestation progresses (ΔBOLD) and in the placental permeability to oxygen (λ). © 2024 International Society of Ultrasound in Obstetrics and Gynecology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Fetal Medicine, Surgery and Imaging, Hôpital Universitaire Necker-Enfants Malades, AP-HP, Paris, France.
- Plateforme LUMIERE, Hôpital Universitaire Necker-Enfants Malades, URP 7328 and PACT, affiliated to Imagine Institut, Université de Paris, Faculté de Médecine, Paris, France.
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
- School of Biomedical Engineering & Imaging Sciences, Kings College London, London, UK.
- Department of Pediatric Radiology, Hôpital Universitaire Necker-Enfants Malades, AP-HP, Paris, France.
- Department of Radiology, Hôpital Louis Mourier, AP-HP, Colombes, France.
ORCID-Profile: R Bartin, L J Salomon
Zitieren
APA
Bartin, R., Melbourne, A., Bobet, L., Gauchard, G., Menneglier, A., Grevent, D., Bussieres, L., Siauve, N., & Salomon, L. J. (2024). Static and dynamic responses to hyperoxia of normal placenta across gestation with T2 *‐weighted MRI sequences. Ultrasound in Obstetrics & Gynecology. https://doi.org/10.1002/uog.27609
Vancouver
Bartin R, Melbourne A, Bobet L, Gauchard G, Menneglier A, Grevent D, et al. Static and dynamic responses to hyperoxia of normal placenta across gestation with T2 *‐weighted MRI sequences. Ultrasound in Obstetrics & Gynecology. 2024. doi:10.1002/uog.27609
BibTeX
@article{Bartin2024,
author = {Bartin, R and Melbourne, A and Bobet, L and Gauchard, G and Menneglier, A and Grevent, D and Bussieres, L and Siauve, N and Salomon, L J},
title = {Static and dynamic responses to hyperoxia of normal placenta across gestation with T2 *‐weighted MRI sequences},
journal = {Ultrasound in Obstetrics & Gynecology},
year = {2024},
doi = {10.1002/uog.27609}
}
EUVIMED