Protection for Arc High‐Resistance Grounding Faults in Active Distribution Networks With Low‐Resistance Grounding

Fengxian Zhao, Chunling Liu, Lin Yuan, Yingjia Sun, Yongqin Li

IEEJ Transactions on Electrical and Electronic Engineering · 2026-12 · 21 (12) · 1839-1847

DOI: 10.1002/tee.70307 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEJ Transactions on Electrical and Electronic Engineering, online erschienen am 06.04.2026. Verfasst von Fengxian Zhao und 4 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Active distribution networks with low‐resistance grounding face a significant challenge under the dual‐carbon strategy. When a single‐phase arcing high‐resistance grounding fault occurs, the resulting zero‐sequence current is weak and unstable. Consequently, existing protection schemes for such faults are rendered ineffective. Considering the neutral points of both the main power grid and the distributed generation (DG) using low‐resistance grounding, the work established an arcing high‐resistance grounding fault model for active distribution networks. The current in the faulty feeder was approximately 180° out of phase with the current at the neutral point due to the transient characteristics of the zero‐sequence current in feeders and at the grid's neutral point. The phase difference between the zero‐sequence current in the healthy feeder without DG and the zero‐sequence current at the neutral point of the main power grid was approximately 90°. However, the phase of the zero‐sequence current in the healthy feeder with DG was approximately in phase with that at the neutral point of the main power grid. A protection method for arc high‐resistance grounding faults in active distribution networks with low‐resistance grounding was proposed based on the waveform similarity of zero‐sequence currents. The proposed protection principle was validated via PSCAD simulations. © 2026 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

Zitieren

APA

Zhao, F., Liu, C., Yuan, L., Sun, Y., & Li, Y. (2026). Protection for Arc High‐Resistance Grounding Faults in Active Distribution Networks With Low‐Resistance Grounding. IEEJ Transactions on Electrical and Electronic Engineering, 21(12), 1839-1847. https://doi.org/10.1002/tee.70307

Vancouver

Zhao F, Liu C, Yuan L, Sun Y, Li Y. Protection for Arc High‐Resistance Grounding Faults in Active Distribution Networks With Low‐Resistance Grounding. IEEJ Transactions on Electrical and Electronic Engineering. 2026;21(12):1839-1847. doi:10.1002/tee.70307

BibTeX
@article{Zhao2026,
  author = {Zhao, Fengxian and Liu, Chunling and Yuan, Lin and Sun, Yingjia and Li, Yongqin},
  title = {Protection for Arc High‐Resistance Grounding Faults in Active Distribution Networks With Low‐Resistance Grounding},
  journal = {IEEJ Transactions on Electrical and Electronic Engineering},
  year = {2026},
  volume = {21},
  number = {12},
  pages = {1839--1847},
  doi = {10.1002/tee.70307}
}