EUVIMEDEUVIMED entdecken
Crossref

Unified Faulty Feeder Detection Criteria and High-Speed Protection Scheme for High Impedance Faults in Resonant Grounding MV Networks

Zhihua Yin, Zhinong Wei, Guoqiang Sun, Sheng Chen, Haixiang Zang

IEEE Transactions on Smart Grid · 2025-09 · 16 (5) · 3653-3665

DOI: 10.1109/tsg.2025.3579803 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Smart Grid, 2025-09. Verfasst von Zhihua Yin und 4 weiteren Autor:innen. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Changzhou Sci&Tech Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The identification of high impedance fault (HIF) is of significant importance for the safe operation of resonant grounding medium voltage (MV) networks. Current protection methods struggle to reliably detect these types of faults, necessitating the urgent development of an effective HIF detection technique. Starting from the differential equation solution of the HIF equivalent circuit, this paper discusses in detail the evolution of the amplitude and polarity characteristics of the zero-sequence current during the transient and steady-state periods after a fault. It demonstrates that the zero-sequence current shares a common evolution process under over damped and under damped fault conditions, leading to the establishment of the unified faulty feeder detection criteria. Upon this discoveries, a novel high-speed protection scheme is introduced. The method, which constructs a pair of mutually orthogonal reference vectors in high-dimensional space, enables independent processing of zero-sequence current signals at each measurement point. This effectively reduces data transmission volume and accelerating detection speed. To validate the accuracy and extensive applicability of the proposed methodology, different fault conditions was conducted both on an active distribution network model and in the field environment. In all instances, HIF characteristics were reliably identified.

Förderung

  • National Natural Science Foundation of China
  • Changzhou Sci&Tech Program

Zitieren

APA

Yin, Z., Wei, Z., Sun, G., Chen, S., & Zang, H. (2025). Unified Faulty Feeder Detection Criteria and High-Speed Protection Scheme for High Impedance Faults in Resonant Grounding MV Networks. IEEE Transactions on Smart Grid, 16(5), 3653-3665. https://doi.org/10.1109/tsg.2025.3579803

Vancouver

Yin Z, Wei Z, Sun G, Chen S, Zang H. Unified Faulty Feeder Detection Criteria and High-Speed Protection Scheme for High Impedance Faults in Resonant Grounding MV Networks. IEEE Transactions on Smart Grid. 2025;16(5):3653-3665. doi:10.1109/tsg.2025.3579803

BibTeX
@article{Yin2025,
  author = {Yin, Zhihua and Wei, Zhinong and Sun, Guoqiang and Chen, Sheng and Zang, Haixiang},
  title = {Unified Faulty Feeder Detection Criteria and High-Speed Protection Scheme for High Impedance Faults in Resonant Grounding MV Networks},
  journal = {IEEE Transactions on Smart Grid},
  year = {2025},
  volume = {16},
  number = {5},
  pages = {3653--3665},
  doi = {10.1109/tsg.2025.3579803}
}
Kostenlos starten →