EUVIMEDEUVIMED entdecken
Crossref

Eccentrically braced frames with short shear links coupled with slip‐critical slotted‐bolted connections

Dariush Mondegar, Iman Shamim

The Structural Design of Tall and Special Buildings · 2026-07 · 35 (7)

DOI: 10.1002/tal.70163 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Structural Design of Tall and Special Buildings, online erschienen am 16.07.2026. Verfasst von Dariush Mondegar und 1 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the seismic performance of eccentrically braced steel frames (EBFs) fabricated with novel slotted‐bolted endplate connections integrated within short shear links. The slotted‐bolted endplate connections are installed either at the shear link's midspan or two ends, representing two feasible installation strategies aimed at dissipating seismically induced energy through frictional resistance without increasing the lateral force demand on braced frames. To validate finite element modeling of the friction mechanism in slotted‐bolted endplate connections, simple frictional bolt connections with slotted holes tested under unidirectional tension are exploited. Additionally, an experimental EBF with a removable short shear link is modeled to extract the details necessary for creating generic steel braced‐frame models. Subsequently, 10 shear links with slip‐critical slotted‐bolted endplate (SCSBE) connections, isolated from the surrounding framing, are numerically examined under cyclic loading with link‐beam sections varying in geometry and bolt fastener configurations from intermediate to heavy duty. The cyclic behavior of EBFs, constructed using the designed shear links, is evaluated for SCSBE connections inserted in the middle and at two ends of shear link beams, revealing substantially greater energy‐dissipation capacity relative to conventional EBFs under the same cyclic loading protocol. Moreover, the design guidelines related to various geometrical and mechanical parameters that influence the EBF's behavior with SCSBE connections, including the friction force limit, bolt arrangement, shear link length, slotted‐hole height, and endplate thickness, are justified by the simulation results.

Zitieren

APA

Mondegar, D., & Shamim, I. (2026). Eccentrically braced frames with short shear links coupled with slip‐critical slotted‐bolted connections. The Structural Design of Tall and Special Buildings, 35(7). https://doi.org/10.1002/tal.70163

Vancouver

Mondegar D, Shamim I. Eccentrically braced frames with short shear links coupled with slip‐critical slotted‐bolted connections. The Structural Design of Tall and Special Buildings. 2026;35(7). doi:10.1002/tal.70163

BibTeX
@article{Mondegar2026,
  author = {Mondegar, Dariush and Shamim, Iman},
  title = {Eccentrically braced frames with short shear links coupled with slip‐critical slotted‐bolted connections},
  journal = {The Structural Design of Tall and Special Buildings},
  year = {2026},
  volume = {35},
  number = {7},
  doi = {10.1002/tal.70163}
}
Kostenlos starten →