EUVIMEDEUVIMED entdecken
Crossref

Fatigue performance analysis of long cantilever cap beam in segmental precast concrete bridge pier

Yan Liang, Syed Basit Ali, Li Yan, Fuqiang Guo, Pin‐Wu Guan

Structural Concrete · 19.06.2026

DOI: 10.1002/suco.70688 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Structural Concrete, online erschienen am 19.06.2026. Verfasst von Yan Liang und 4 weiteren Autor:innen. Die Arbeit nennt 44 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As bridge construction trends toward industrialized, large‐span solutions, segmental precast technology has gained prominence for its efficiency, quality control, and environmental benefits. The long cantilever cap beam, a vital connection between superstructure and substructure, plays a key role in transferring loads to bridge piers, especially in urban areas with limited space. Despite the increasing use of segmental precast methods, limited research exists on the fatigue performance of such cap beams under prolonged traffic and environmental loading. This study examines the fatigue behavior of a segmental precast long cantilever cap beam through a real engineering case. Finite element models were developed in ABAQUS finite element analysis software (ABAQUS) and Finite Element (FE)‐Safe to simulate static and fatigue conditions, integrating actual traffic data and material degradation from corrosion. Fatigue loads were derived using Miner's linear damage theory and equivalent damage principles. The results indicate that the cantilever end develops the largest deflection during service life, primarily owing to fatigue accumulation and the early onset of material deterioration. Prestressed tendons at joints consistently experience higher tensile stress than those in segments due to earlier corrosion onset. Nonetheless, concrete remains in compression and reinforcement stress stays within design limits, confirming the beam's structural reliability under combined fatigue and durability effects. These findings provide a useful basis for the design optimization, durability assessment, and maintenance planning of segmental precast cap beams in space‐constrained urban bridge projects.

Zitieren

APA

Liang, Y., Ali, S. B., Yan, L., Guo, F., & Guan, P. (2026). Fatigue performance analysis of long cantilever cap beam in segmental precast concrete bridge pier. Structural Concrete. https://doi.org/10.1002/suco.70688

Vancouver

Liang Y, Ali SB, Yan L, Guo F, Guan P. Fatigue performance analysis of long cantilever cap beam in segmental precast concrete bridge pier. Structural Concrete. 2026. doi:10.1002/suco.70688

BibTeX
@article{Liang2026,
  author = {Liang, Yan and Ali, Syed Basit and Yan, Li and Guo, Fuqiang and Guan, Pin‐Wu},
  title = {Fatigue performance analysis of long cantilever cap beam in segmental precast concrete bridge pier},
  journal = {Structural Concrete},
  year = {2026},
  doi = {10.1002/suco.70688}
}
Kostenlos starten →