EUVIMEDEUVIMED entdecken
Crossref

Macroscopic characteristics and mechanism of concrete with self‐ignited coal gangue as sand under different steam curing parameters

Meng Wang, Boling Liu, Wanwan Yu

Structural Concrete · 2025-12 · 26 (6) · 7473-7488

DOI: 10.1002/suco.202401409 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Structural Concrete, online erschienen am 25.02.2025. Verfasst von Meng Wang und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The objective of this study is to optimize the steam curing parameters of concrete using spontaneous combustion coal gangue (SCG) as sand, thereby promoting the application potential of this solid waste‐based material in precast component production. In light of the current insufficient research on the steam curing mechanism and performance optimization of SCG sand concrete, multiple experiments were designed and conducted under various curing conditions to systematically evaluate its macroscopic mechanical properties and microscopic structural characteristics. This research employed axial compression and splitting tensile tests to analyze the influence of curing conditions on compressive strength and splitting tensile strength. Furthermore, backscattered electron scanning electron microscopy and microhardness testing were utilized to compare the width and microhardness variations of the interface transition zone (ITZ) under different curing conditions. The results indicate that, irrespective of the use of river sand or manufactured sand, steam‐cured concrete exhibits higher early‐stage mechanical performance compared to standard‐cured concrete. However, elevated temperatures lead to an uneven distribution of hydration products, hindering subsequent hydration reactions and causing varying degrees of deterioration in later‐stage mechanical performance. Based on the microscopic test results, it is concluded that pore size coarsening, increased gaps in the ITZ, and the loose structure of hydration products are the primary reasons for the deterioration of later‐stage performance in steam‐cured concrete. Notably, substituting river sand with SCG sand can effectively mitigate the adverse effects caused by the thermal damage associated with steam curing. Additionally, longer precuring times, shorter constant temperature curing durations, and lower curing temperatures result in enhanced mechanical performance and improved microscopic structure of SCG sand concrete, manifested as a more refined pore structure, smaller gaps in the ITZ, and higher average microhardness in the matrix, leading to greater overall density. Based on comprehensive analysis, the optimal steam curing parameters are determined to be 4 h of precuring time, followed by 6 h at a curing temperature of 60°C. These findings provide valuable insights for the efficient production of prefabricated components utilizing SCG sand concrete.

Zitieren

APA

Wang, M., Liu, B., & Yu, W. (2025). Macroscopic characteristics and mechanism of concrete with self‐ignited coal gangue as sand under different steam curing parameters. Structural Concrete, 26(6), 7473-7488. https://doi.org/10.1002/suco.202401409

Vancouver

Wang M, Liu B, Yu W. Macroscopic characteristics and mechanism of concrete with self‐ignited coal gangue as sand under different steam curing parameters. Structural Concrete. 2025;26(6):7473-7488. doi:10.1002/suco.202401409

BibTeX
@article{Wang2025,
  author = {Wang, Meng and Liu, Boling and Yu, Wanwan},
  title = {Macroscopic characteristics and mechanism of concrete with self‐ignited coal gangue as sand under different steam curing parameters},
  journal = {Structural Concrete},
  year = {2025},
  volume = {26},
  number = {6},
  pages = {7473--7488},
  doi = {10.1002/suco.202401409}
}
Kostenlos starten →