EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Experimental and analytical study on the load‐bearing capacity of segmented tower structures with dry joints under combined loading

Florian Fürll, Fabian Klein, Steffen Hartwig, Chongjie Kang, Thorsten Betz, Steffen Marx

Structural Concrete · 2024-10 · 25 (5) · 3347-3360

DOI: 10.1002/suco.202300873 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Structural Concrete, online erschienen am 18.06.2024. Verfasst von Florian Fürll und 5 weiteren Autor:innen. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, hybrid towers have become increasingly established, especially for tall wind turbines. The concrete part of these towers, commonly constructed using segmental construction methods, consists of several circular ring segments stacked on top of each other. To reduce the amount of fabrication and erection effort, the joints between the segments are typically designed as dry ground joints. This paper deals with experimental investigations to determine the torsional load‐bearing capacity of such dry ground concrete joints subjected to combined loading of prestressing, bending, and torsion. Based on the experience of previous investigations, a test set‐up consisting of three reinforced concrete segments with circular ring cross‐sections was developed. The herein newly developed evaluation concept enabled precise identification of the failure point for each test run utilizing the measured tangential displacements of the joint. The test results clarify the weaknesses of the current design model regarding the insufficient interaction with the bending moment and show very good accordance with the new calculation model, the so‐called fiber model.

Zitieren

APA

Fürll, F., Klein, F., Hartwig, S., Kang, C., Betz, T., & Marx, S. (2024). Experimental and analytical study on the load‐bearing capacity of segmented tower structures with dry joints under combined loading. Structural Concrete, 25(5), 3347-3360. https://doi.org/10.1002/suco.202300873

Vancouver

Fürll F, Klein F, Hartwig S, Kang C, Betz T, Marx S. Experimental and analytical study on the load‐bearing capacity of segmented tower structures with dry joints under combined loading. Structural Concrete. 2024;25(5):3347-3360. doi:10.1002/suco.202300873

BibTeX
@article{Frll2024,
  author = {Fürll, Florian and Klein, Fabian and Hartwig, Steffen and Kang, Chongjie and Betz, Thorsten and Marx, Steffen},
  title = {Experimental and analytical study on the load‐bearing capacity of segmented tower structures with dry joints under combined loading},
  journal = {Structural Concrete},
  year = {2024},
  volume = {25},
  number = {5},
  pages = {3347--3360},
  doi = {10.1002/suco.202300873}
}
Kostenlos starten →