Fachartikel in der Zeitschrift Small Structures, online erschienen am 30.04.2026. Verfasst von Nayeon Kwon und 15 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Diabetes is a growing global health concern that requires continuous glucose monitoring. Conventional methods involve painful blood sampling, which is particularly challenging for young and elderly patients. Microneedle (MN) emerges as minimally invasive devices that enable blood glucose monitoring without pain. However, most reported MN sensors rely on amperometric methods, which reduce biocompatibility due to mediator release and toxicity. To address this, acetic acid and chitosan MN (A.C. MN) were fabricated using biocompatible chitosan and glycerin for mechanical strength. Glucose oxidase (GOx) is incorporated as a probe, enabling glucose detection without additional immobilization. The A.C. MN array (15 × 15, 700 μm length) absorbs ≈5 μL of interstitial fluid in agarose skin models and nude mice. An optical biosensor integrated with a Bluetooth module captures GOx‐mediated colorimetric responses and transmits real‐time glucose data. Luminosity values increase linearly with glucose concentration, achieving a detection limit of 23.9 mg dL −1 . Specificity tests confirm selective glucose detection in interstitial fluid. In vivo evaluation using diabetic and normal mice demonstrates distinct glucose responses, validating device functionality. This minimally invasive A.C. MN biosensor eliminates enzyme immobilization steps, enhances patient comfort, and provides portable real‐time monitoring, making it a promising platform for glucose management.
Zitieren
APA
Kwon, N., Hong, Y., Yoo, D., Eo, Y., Jung, S., Yang, H., Lee, J., Lee, S., Jang, W., Kim, H., Heo, D. N., Yoon, J., Kwon, I. K., Yang, D. H., Min, J., & Lee, T. (2026). Fabrication of Transparent Microneedle Patch for Minimally Invasive Glucose Monitoring Optical Biosensor. Small Structures, 7(5). https://doi.org/10.1002/sstr.70437
Vancouver
Kwon N, Hong Y, Yoo D, Eo Y, Jung S, Yang H, et al. Fabrication of Transparent Microneedle Patch for Minimally Invasive Glucose Monitoring Optical Biosensor. Small Structures. 2026;7(5). doi:10.1002/sstr.70437
BibTeX
@article{Kwon2026,
author = {Kwon, Nayeon and Hong, Yerin and Yoo, Daehyeon and Eo, Yongsuk and Jung, Seokho and Yang, Hoesung and Lee, Jinah and Lee, Siyun and Jang, WonJun and Kim, Han‐Jun and Heo, Dong Nyoung and Yoon, Jinwook and Kwon, Il Keun and Yang, Dae Hyeok and Min, Junhong and Lee, Taek},
title = {Fabrication of Transparent Microneedle Patch for Minimally Invasive Glucose Monitoring Optical Biosensor},
journal = {Small Structures},
year = {2026},
volume = {7},
number = {5},
doi = {10.1002/sstr.70437}
}