Electrochemical Detection of Prostate Cancer—Associated miRNA-141 Using a Low-Cost Disposable Biosensor

Alexander Hunt, Gymama Slaughter iD

Biosensors · 06.06.2025 · 15 (6) · 364

DOI: 10.3390/bios15060364 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 06.06.2025. Verfasst von Alexander Hunt und 1 weiteren Autor:innen. Beteiligte Einrichtung: Center for Bioelectronics, Old Dominion University, Norfolk, VA 23508, USA. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, Prostatic Neoplasms, Electrochemical Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Prostate cancer is the second leading cause of cancer-related deaths among men in the United States. The early detection of aggressive forms is critical. Current diagnostic methods, including PSA testing and biopsies, are invasive and often yield false results. MicroRNA-141 (miRNA-141) has emerged as a promising non-invasive biomarker due to its elevated levels in the urine of patients with metastatic prostate cancer. Here, a low-cost, paper-based electrochemical biosensor for the sensitive detection of miRNA-141 in synthetic urine is reported. The device employs inkjet-printed gold electrodes on photopaper, functionalized with thiolated single-stranded DNA-141 capture probes for specific target recognition. The biosensor achieves a sensitivity of 78.66 fM µA−1 cm−2 and a linear detection range of 1 fM to 100 nM, encompassing clinically relevant concentrations of miRNA-141 found in patients with metastatic prostate cancer. A low limit of detection of 2.15 fM, strong selectivity against non-target sequences, and a rapid response time of 15 min further highlight the diagnostic potential of the device. This platform represents a significant advancement in the development of point-of-care diagnostic tools for prostate cancer and is readily adaptable for detecting other disease-specific miRNAs through simple probe modification. As such, it holds broad promise for accessible, early-stage cancer detection and longitudinal disease monitoring in diverse clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsBiosensing TechniquesProstatic NeoplasmsElectrochemical TechniquesMaleHumansBiomarkers, TumorLimit of DetectionElectrodes

Stichwörter der Autor:innen

gold inkjet printingmicroRNA-141 detectionpaper-based electrochemical biosensorprostate cancersynthetic urine

Substanzen

MicroRNAsMIRN141 microRNA, humanBiomarkers, Tumor

Autor:innen und Institutionen

  • Center for Bioelectronics, Old Dominion University, Norfolk, VA 23508, USA.
  • Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA 23508, USA.

ORCID-Profile: Gymama Slaughter

Zitieren

APA

Hunt, A., & Slaughter, G. (2025). Electrochemical Detection of Prostate Cancer—Associated miRNA-141 Using a Low-Cost Disposable Biosensor. Biosensors, 15(6), 364. https://doi.org/10.3390/bios15060364

Vancouver

Hunt A, Slaughter G. Electrochemical Detection of Prostate Cancer—Associated miRNA-141 Using a Low-Cost Disposable Biosensor. Biosensors. 2025;15(6):364. doi:10.3390/bios15060364

BibTeX
@article{Hunt2025,
  author = {Hunt, Alexander and Slaughter, Gymama},
  title = {Electrochemical Detection of Prostate Cancer—Associated miRNA-141 Using a Low-Cost Disposable Biosensor},
  journal = {Biosensors},
  year = {2025},
  volume = {15},
  number = {6},
  pages = {364},
  doi = {10.3390/bios15060364}
}
Kostenlos starten →