EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Electrochemical and Biological Evaluation of Patterned TiO 2 @TiC‐Nanowires for Bio‐Interface Electrode

Roaa Sait iD, Shofarul Wustoni iD, Nabeel Aslam, Camelia Florica iD, Andrea Diaz-Gaxiola iD, Valentina-Elena Musteata iD, Mohammed K Drad iD, Stephen Ghandour iD, Georgian Melinte iD, Yaping Zhang iD, Mohammed Nejib Hedhili iD, Ahad Ali Syed iD und 5 weitere

Small · 2026-11 · 22 (61)

DOI: 10.1002/smll.75473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, online erschienen am 01.09.2026. Verfasst von Roaa Sait und 16 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Science, Department of Physics, King Abdulaziz University (KAU), Jeddah, Saudi Arabia. Hauptthemen laut MEDLINE: Titanium, Nanowires, Electrochemical Techniques. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: This research received no external funding.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The next generation of bioelectronic interfaces demands materials that integrate biocompatibility, robust electrochemical performance and architectural functionality. Here, we introduce a low‐temperature fabrication approach for patterned titanium oxide‐coated titanium carbide nanowires (P‐TiO 2 @TiC‐NWs), utilizing room‐temperature sputter deposition, avoiding high‐temperature carbide synthesis. TiO 2 @TiC‐NWs combine the high‐aspect‐ratio architecture of TiO 2 ‐NWs with the electrochemical performance of TiC, providing a tunable platform for bioelectronic interface design. By tuning sputtering pressure and duration, distinct TiC shell morphologies and compositions were engineered. Low‐pressure deposition produced a uniform conductive shell, favoring faster charge dynamics and a more ideal capacitive response, while high‐pressure deposition generated a carbon‐rich, cauliflower‐like morphology that increased electrochemically accessible surface area. TiO 2 @TiC‐NWs reached areal capacitances of 1.01 and 2.25 mF cm − 2 for 20 min deposition at 3 and 10 mTorr, respectively, compared with 117 µF cm − 2 and 1.35 mF cm − 2 for the corresponding planar TiC films. After 3000 cycles in physiological buffer, the 10 mTorr, 20 min sputtered sample retained 86% capacitance, while the 3 mTorr retained 75%. C2C12 myotubes cultured on P‐TiO 2 @TiC‐NW substrates exhibited preferential adhesion and directional alignment along the nanowire stripe axis, demonstrating the capacity of nanoscale surface topography to instruct anisotropic cell organization. Together, these features highlight P‐TiO 2 @TiC‐NWs as promising bioelectronic interfaces.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumNanowiresElectrochemical TechniquesElectrodesAnimalsMice

Stichwörter der Autor:innen

C2C12 myotubescyclic voltammetryimpedancenanowiressputter depositiontitanium carbidetitanium oxide

Substanzen

Titaniumtitanium dioxidetitanium carbide

Autor:innen und Institutionen

  • Faculty of Science, Department of Physics, King Abdulaziz University (KAU), Jeddah, Saudi Arabia.
  • Organic Bioelectronics Laboratory, Biological Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia.
  • Core Labs, King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia.
  • BESE, Bioscience Program, King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia.
  • Stem Cells, Organoid & Precise Engineering (SCOPE) Platform, King Abdullah University of Science and Technology (KAUST), Thuwal, Saudi Arabia.

ORCID-Profile: Roaa Sait, Shofarul Wustoni, Camelia Florica, Andrea Diaz-Gaxiola, Valentina-Elena Musteata, Mohammed K Drad, Stephen Ghandour, Georgian Melinte, Yaping Zhang, Mohammed Nejib Hedhili, Ahad Ali Syed, Shahryar Khattak, Sahika Inal, Hala Aljawhari

Förderung

  • This research received no external funding

Zitieren

APA

Sait, R., Wustoni, S., Aslam, N., Florica, C., Diaz-Gaxiola, A., Musteata, V. E., Drad, M. K., Ghandour, S., Melinte, G., Zhang, Y., Hedhili, M. N., Syed, A. A., Saidani, M., Khattak, S., Eddine-Gallouzi, I., Inal, S., & Aljawhari, H. (2026). Electrochemical and Biological Evaluation of Patterned TiO 2 @TiC‐Nanowires for Bio‐Interface Electrode. Small, 22(61). https://doi.org/10.1002/smll.75473

Vancouver

Sait R, Wustoni S, Aslam N, Florica C, Diaz-Gaxiola A, Musteata VE, et al. Electrochemical and Biological Evaluation of Patterned TiO 2 @TiC‐Nanowires for Bio‐Interface Electrode. Small. 2026;22(61). doi:10.1002/smll.75473

BibTeX
@article{Sait2026,
  author = {Sait, Roaa and Wustoni, Shofarul and Aslam, Nabeel and Florica, Camelia and Diaz-Gaxiola, Andrea and Musteata, Valentina-Elena and Drad, Mohammed K and Ghandour, Stephen and Melinte, Georgian and Zhang, Yaping and Hedhili, Mohammed Nejib and Syed, Ahad Ali and Saidani, Menouer and Khattak, Shahryar and Eddine-Gallouzi, Imed and Inal, Sahika and Aljawhari, Hala},
  title = {Electrochemical and Biological Evaluation of Patterned TiO 2 @TiC‐Nanowires for Bio‐Interface Electrode},
  journal = {Small},
  year = {2026},
  volume = {22},
  number = {61},
  doi = {10.1002/smll.75473}
}
Kostenlos starten →