EUVIMEDEUVIMED entdecken
Open Access

Operando Diagnosis of Acidic CO 2 Electroreduction Degradation Mechanism in a Zero‐Gap Electrolyzer via the Distribution of Relaxation Times

Zheng Chen iD, Xiongwei Tian iD, Mengyin Xie, Wenqing Chu, RuoYu Wu, Yuqun Zhuo

Small · 2026-09 · 22 (51)

DOI: 10.1002/smll.74672 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, online erschienen am 05.08.2026. Verfasst von Zheng Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Thermal Science and Power Engineering of the Ministry of Education, Department of Energy and Power Engineering, Tsinghua University…. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acidic CO 2 electroreduction (CO 2 R) in membrane electrode assemblies (MEAs) offers a promising route for high‐performance electrolysis but remains limited by poor stability. Here, we integrate operando electrochemical impedance spectroscopy (EIS) with distribution of relaxation times (DRT) analysis to diagnose the key processes governing acidic CO 2 R in MEAs. Comparative evaluation of Nafion and phosphoric‐acid‐doped polybenzimidazole (PA‐PBI) membranes shows that PA‐PBI effectively suppresses salt precipitation, providing a reliable basis for interpreting DRT spectra. By systematically adjusting electrolysis parameters, distinct features associated with interfacial contact resistance, anodic/cathodic ionic conduction, charge transfer, and CO 2 transport are resolved in DRT spectra. Furthermore, stability tests with DRT analysis reveal rapid failure of Nafion‐based MEA (∼0.5 h) due to salt accumulation, whereas the PA‐PBI‐based MEA operates for 103 h before CO 2 mass‐transport limitations arise. These findings demonstrate operando EIS‐DRT as a powerful diagnostic tool and provide mechanistic guidance for designing long‐lasting acidic CO 2 R MEAs.

Schlagwörter

Stichwörter der Autor:innen

acidic CO2 electroreductiondegradation mechanismsdistribution of relaxation timeselectrochemical impedance spectroscopymembrane electrode assembly

Autor:innen und Institutionen

  • Key Laboratory of Thermal Science and Power Engineering of the Ministry of Education, Department of Energy and Power Engineering, Tsinghua University, Beijing, China.
  • Shanxi Research Institute for Clean Energy, Tsinghua University, Taiyuan, China.

ORCID-Profile: Zheng Chen, Xiongwei Tian

Förderung

  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Chen, Z., Tian, X., Xie, M., Chu, W., Wu, R., & Zhuo, Y. (2026). Operando Diagnosis of Acidic CO 2 Electroreduction Degradation Mechanism in a Zero‐Gap Electrolyzer via the Distribution of Relaxation Times. Small, 22(51). https://doi.org/10.1002/smll.74672

Vancouver

Chen Z, Tian X, Xie M, Chu W, Wu R, Zhuo Y. Operando Diagnosis of Acidic CO 2 Electroreduction Degradation Mechanism in a Zero‐Gap Electrolyzer via the Distribution of Relaxation Times. Small. 2026;22(51). doi:10.1002/smll.74672

BibTeX
@article{Chen2026,
  author = {Chen, Zheng and Tian, Xiongwei and Xie, Mengyin and Chu, Wenqing and Wu, RuoYu and Zhuo, Yuqun},
  title = {Operando Diagnosis of Acidic CO 2 Electroreduction Degradation Mechanism in a Zero‐Gap Electrolyzer via the Distribution of Relaxation Times},
  journal = {Small},
  year = {2026},
  volume = {22},
  number = {51},
  doi = {10.1002/smll.74672}
}
Kostenlos starten →