EUVIMEDEUVIMED entdecken
Crossref

Photoexcited Electro‐Driven Reactive Oxygen Species Channeling for Precise Extraction of Biomarker Information from Tumor Interstitial Fluid

Xiyue Xie, Shuqi Tang, Chunhui Zhai, Kaixiu Fu, Fan Li, Kaiyong Cai, Jixi Zhang iD

Small · 2025

DOI: 10.1002/smll.202410358 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Small, 2025. Verfasst von Xiyue Xie und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Roa…. Hauptthemen laut MEDLINE: Reactive Oxygen Species, Biomarkers, Tumor, Extracellular Fluid. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Chongqing, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Direct electrochemical detection of miRNA biomarkers in tumor tissue interstitial fluid (TIF) holds great promise for adjuvant therapy for tumors in the perioperative period, yet is limited by background interference and weak signal. Herein, a wash‐free and separation‐free miRNA biosensor based on photoexcited electro‐driven reactive oxygen channeling analysis (LEOCA) is developed to solve the high‐fidelity detection in physiological samples. In the presence of miRNA, nanoacceptors (ultrasmall‐size polydopamine, uPDA) are responsively assembled on the surface of nanodonors (zirconium metal‐organic framework, ZrMOF) to form core‐satellite aggregates. The produced lifetime‐constraint singlet oxygen upon light irradiation is captured by the catechol of constrained uPDA, and the oxidized quinone is immediately electro‐reduced to the catechol at transient collision process on the electrode, resulting in a cascade electron transfer and amplified current. Thereby, the nanosensor exhibits a low detection limit (1.1 fM), and high reproducibility (relative standard deviation of 2.0%). Compared with quantitative real‐time polymerase chain reaction (qRT‐PCR), the clinical accuracy (area under the curve value) is significantly increased from 0.75 to 0.93 in distinguishing breast cancer patients from healthy donors. This study demonstrates an inspiration on the synergy of the reactive oxygen channeling between nanodonor/nanoacceptor and the synchronous electron transfer cascade on the electrode to solve the bottleneck problem of detecting unprocessed clinical samples in a sample‐in‐answer‐out manner.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Reactive Oxygen SpeciesBiomarkers, TumorExtracellular FluidHumansMicroRNAsBiosensing TechniquesFemaleElectrochemical TechniquesIndolesPolymers

Stichwörter der Autor:innen

biomarker sensingelectron transferfunctional aggregatesinterface collisionphotoelectric coupling

Substanzen

Reactive Oxygen SpeciesBiomarkers, TumorMicroRNAspolydopamineIndolesPolymers

Autor:innen und Institutionen

  • Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No. 174 Shazheng Road, Chongqing, 400044, China.
  • State Key Laboratory of Digital Medical Engineering, Jiangsu Key Laboratory for Biomaterials and Devices, School of Biological Science and Medical Engineering, Southeast University, Nanjing, 210096, China.
  • Department of Breast and Thyroid Surgery, The First Affiliated Hospital of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, China.

ORCID-Profile: Jixi Zhang

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Chongqing
  • Fundamental Research Funds for the Central Universities
  • 100 Talents Program of Chongqing University
  • Natural Science Foundation of Chongqing Municipality

Zitieren

APA

Xie, X., Tang, S., Zhai, C., Fu, K., Li, F., Cai, K., & Zhang, J. (2025). Photoexcited Electro‐Driven Reactive Oxygen Species Channeling for Precise Extraction of Biomarker Information from Tumor Interstitial Fluid. Small. https://doi.org/10.1002/smll.202410358

Vancouver

Xie X, Tang S, Zhai C, Fu K, Li F, Cai K, et al. Photoexcited Electro‐Driven Reactive Oxygen Species Channeling for Precise Extraction of Biomarker Information from Tumor Interstitial Fluid. Small. 2025. doi:10.1002/smll.202410358

BibTeX
@article{Xie2025,
  author = {Xie, Xiyue and Tang, Shuqi and Zhai, Chunhui and Fu, Kaixiu and Li, Fan and Cai, Kaiyong and Zhang, Jixi},
  title = {Photoexcited Electro‐Driven Reactive Oxygen Species Channeling for Precise Extraction of Biomarker Information from Tumor Interstitial Fluid},
  journal = {Small},
  year = {2025},
  doi = {10.1002/smll.202410358}
}
Kostenlos starten →