An Ultrasensitive Ti 3 C 2 T x MXene‐based Soft Contact Lens for Continuous and Nondestructive Intraocular Pressure Monitoring
Small · 2024
DOI: 10.1002/smll.202309785 ↗Kurz gefasst
Fachartikel in der Zeitschrift Small, 2024. Verfasst von Zhongyi Duan und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing, 100081, P. R. China. Hauptthemen laut MEDLINE: Intraocular Pressure, Contact Lenses, Hydrophilic, Titanium. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Natural Science Foundation, Natural Science Foundation of Beijing Municipality.
Abstract (Originalsprache)
Wearable soft contact lens sensors for continuous and nondestructive intraocular pressure (IOP) monitoring are highly desired as glaucoma and postoperative myopia patients grow, especially as the eyestrain crowd increases. Herein, a smart closed‐loop system is presented that combines a Ti 3 C 2 T x MXene‐based soft contact lens (MX‐CLS) sensor, wireless data transmission units, display, and warning components to realize continuous and nondestructive IOP monitoring/real‐time display. The fabricated MX‐CLS device exhibits an extremely high sensitivity of 7.483 mV mmHg −1 , good linearity on silicone eyeballs, excellent stability under long‐term pressure‐release measurement, sufficient transparency with 67.8% transmittance under visible illumination, and superior biocompatibility with no discomfort when putting the MX‐CLS sensor onto the Rabbit eyes. After integrating with the wireless module, users can realize real‐time monitoring and warning of IOP via smartphones, the demonstrated MX‐CLS device together with the IOP monitoring/display system opens up promising platforms for Ti 3 C 2 T x materials as the base for multifunctional contact lens‐based sensors and continuous and nondestructive IOP measurement system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing, 100081, P. R. China.
- State Key Laboratory of Integrated Optoelectronics Institute of Semiconductors, Chinese Academy of Sciences, Beijing, 100083, P. R. China.
- School of Physics, Beijing Institute of Technology, Beijing, 100081, P. R. China.
- Faculty of Hepato-Pancreato-Biliary Surgery, Chinese PLA General Hospital, Institute of Hepatobiliary Surgery of Chinese PLA & Key Laboratory of Digital Hepatobiliary Surgery, Beijing, 100853, P. R. China.
ORCID-Profile: Weihua Pei, La Li, Guozhen Shen
Förderung
- National Natural Science Foundation of China
- Beijing Natural Science Foundation
- Natural Science Foundation of Beijing Municipality
Zitieren
APA
Duan, Z., Yuan, M., Liu, Z., Pei, W., Jiang, K., Li, & Shen, G. (2024). An Ultrasensitive Ti 3 C 2 T x MXene‐based Soft Contact Lens for Continuous and Nondestructive Intraocular Pressure Monitoring. Small. https://doi.org/10.1002/smll.202309785
Vancouver
Duan Z, Yuan M, Liu Z, Pei W, Jiang K, Li, et al. An Ultrasensitive Ti 3 C 2 T x MXene‐based Soft Contact Lens for Continuous and Nondestructive Intraocular Pressure Monitoring. Small. 2024. doi:10.1002/smll.202309785
BibTeX
@article{Duan2024,
author = {Duan, Zhongyi and Yuan, Miao and Liu, Zhiduo and Pei, Weihua and Jiang, Kai and Li, La and Shen, Guozhen},
title = {An Ultrasensitive Ti 3 C 2 T x MXene‐based Soft Contact Lens for Continuous and Nondestructive Intraocular Pressure Monitoring},
journal = {Small},
year = {2024},
doi = {10.1002/smll.202309785}
}
EUVIMED