Crack-Enhanced MXene-Carbon Nanotube Soft Contact Lens for Body-Induced Intracranial Pressure Application
ACS Nano · 2025
DOI: 10.1021/acsnano.4c18484 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Nano, 2025. Verfasst von Lifeng Wu und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing 100081, China. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Intracranial Pressure, Contact Lenses, Hydrophilic. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: Natural Science Foundation of Beijing Municipality, National Natural Science Foundation of China, BIT Research and Innovation Promoting Project.
Abstract (Originalsprache)
Continuous monitoring of intracranial pressure (ICP) can guarantee stable vital signs and help avoid the risk of debilitating headaches, transient ocular blindness, and optic atrophy caused by elevated ICP, which are critical for patients or specific groups like astronauts and athletes. However, in situ ICP detection typically relies on neural pixels that require a surgical procedure, such as a craniotomy. Here, we report a continuous and nondestructive ICP detection approach via an in situ intraocular pressure (IOP) monitoring system, which includes a pressure response unit using a microcracked MXene@carboxylated carbon nanotube (C-MWCNT) IOP sensor with Wheatstone bridge architecture, an electrical circuit, and a mobile platform to record and display the IOP value. Inspired by the ″lotus root″, the microcracked MXene@C-MWCNT IOP sensor capabilities include both high sensitivity of 33.21 mV/mmHg and a wide monitoring range of 60 mmHg, ensuring real-time IOP monitoring and early warning of elevated IOP or ICP levels. The real-time IOP and ICP data recorded by live rabbits wearing our devices or embedding a commercial implant probe show superior consistency across different body positions, demonstrating the feasibility of ICP monitoring using the eye-wearable IOP sensor system and its potential applications in cerebrovascular/ophthalmic diagnosis and treatment, as well as astronaut training.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing 100081, China.
ORCID-Profile: La Li, Guozhen Shen
Förderung
- Natural Science Foundation of Beijing Municipality
- National Natural Science Foundation of China
- BIT Research and Innovation Promoting Project
Zitieren
APA
Wu, L., Du, Z., Liu, W., Duan, Z., Liu, H., Li, & Shen, G. (2025). Crack-Enhanced MXene-Carbon Nanotube Soft Contact Lens for Body-Induced Intracranial Pressure Application. ACS Nano. https://doi.org/10.1021/acsnano.4c18484
Vancouver
Wu L, Du Z, Liu W, Duan Z, Liu H, Li, et al. Crack-Enhanced MXene-Carbon Nanotube Soft Contact Lens for Body-Induced Intracranial Pressure Application. ACS Nano. 2025. doi:10.1021/acsnano.4c18484
BibTeX
@article{Wu2025,
author = {Wu, Lifeng and Du, Zhijian and Liu, Weijia and Duan, Zhongyi and Liu, Haiqing and Li, La and Shen, Guozhen},
title = {Crack-Enhanced MXene-Carbon Nanotube Soft Contact Lens for Body-Induced Intracranial Pressure Application},
journal = {ACS Nano},
year = {2025},
doi = {10.1021/acsnano.4c18484}
}
EUVIMED