EUVIMEDOpdag EUVIMED
Crossref

Chitosan Versus Carboxymethyl Cellulose Magnetic Solid‐Phase Extraction of Methylparaben and Propylparaben in Pharmaceutical Syrups: An Analytical Quality by Design‐Driven Assessment of Matrix Interaction and Performance Limitations

Raneem J. Darraj, Mohammad F. Haroun, Ayat abbood, Ibrahim alghoraibi

ChemistrySelect · 2026-11 · 11 (42)

DOI: 10.1002/slct.75134 ↗

At a glance

Journal article in ChemistrySelect, published online on 2026-11-09. Written by Raneem J. Darraj and 3 co-authors. 27 references.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Magnetic solid‐phase extraction (MSPE) is increasingly used in pharmaceutical analysis, yet biopolymer‐based sorbents in complex matrices remain poorly understood. This AQbD‐driven study evaluates two biopolymer‐coated magnetite nanoparticles—chitosan (cationic) and carboxymethyl cellulose (CMC, anionic)—for extracting methylparaben (MP) and propylparaben (PP) from pharmaceutical syrups. The workflow included ATP definition, Ishikawa/FMEA risk assessment, and Box‐Behnken optimization. Chitosan achieved 48.0 ± 0.7% absolute recovery in real syrups, whereas CMC failed (< 5%) despite ∼70% in aqueous media; matrix‐induced aggregation and sorption‐site blocking by cationic excipients are proposed. Accuracy by standard addition was 97.2%–98.5% (RSD ≤ 2.9%). Matrix interactions were not independently quantified because standard addition corrects for signal suppression and extraction losses. Linearity was 0.5–20 µg mL − 1 (MP) and 0.25–10 µg mL − 1 (PP), R 2 > 0.998, with LODs 0.05–0.15 µg mL − 1 and LOQs 0.15–0.45 µg mL − 1 . Greenness assessment (Eco‐Scale 84, AGREE 0.64/1) and BAGI (65.0) confirmed sustainability and practical applicability. This study benchmarks biopolymer‐based MSPE limitations in complex matrices and challenges the assumption that high recovery in simple matrices translates to real‐sample performance.

Cite

APA

Darraj, R. J., Haroun, M. F., abbood, A., & alghoraibi, I. (2026). Chitosan Versus Carboxymethyl Cellulose Magnetic Solid‐Phase Extraction of Methylparaben and Propylparaben in Pharmaceutical Syrups: An Analytical Quality by Design‐Driven Assessment of Matrix Interaction and Performance Limitations. ChemistrySelect, 11(42). https://doi.org/10.1002/slct.75134

Vancouver

Darraj RJ, Haroun MF, abbood A, alghoraibi I. Chitosan Versus Carboxymethyl Cellulose Magnetic Solid‐Phase Extraction of Methylparaben and Propylparaben in Pharmaceutical Syrups: An Analytical Quality by Design‐Driven Assessment of Matrix Interaction and Performance Limitations. ChemistrySelect. 2026;11(42). doi:10.1002/slct.75134

BibTeX
@article{Darraj2026,
  author = {Darraj, Raneem J. and Haroun, Mohammad F. and abbood, Ayat and alghoraibi, Ibrahim},
  title = {Chitosan Versus Carboxymethyl Cellulose Magnetic Solid‐Phase Extraction of Methylparaben and Propylparaben in Pharmaceutical Syrups: An Analytical Quality by Design‐Driven Assessment of Matrix Interaction and Performance Limitations},
  journal = {ChemistrySelect},
  year = {2026},
  volume = {11},
  number = {42},
  doi = {10.1002/slct.75134}
}
Start for free →