EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions

Junyoung Park iD, Neo Kok, Irina Gaynanova iD

Statistics in Medicine · 2026-07 · 45 (15-17)

DOI: 10.1002/sim.70646 ↗

At a glance

Journal article in Statistics in Medicine, published online on 2026-06-30. Written by Junyoung Park and 2 co-authors. Institution: Department of Biostatistics, University of Michigan, Ann Arbor, Michigan, USA. Major MEDLINE topics: Wearable Electronic Devices. 49 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, National Institutes of Health.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Wearable devices, such as actigraphy monitors and continuous glucose monitors (CGMs), capture high‐frequency data, which are often summarized by the percentages of time spent within fixed thresholds. For example, actigraphy data are categorized into sedentary, light, and moderate‐to‐vigorous activity, while CGM data are divided into hypoglycemia, normoglycemia, and hyperglycemia based on a standard glucose range of 70–180 mg/dL. Although scientific and clinical guidelines inform the choice of thresholds, it remains unclear whether this choice is optimal and whether the same thresholds should be applied across different populations. In this work, we define threshold optimality with loss functions that quantify discrepancies between the full empirical distributions of wearable device measurements and their discretizations based on specific thresholds. We introduce two loss functions: one that aims to accurately reconstruct the original distributions and another that preserves the pairwise sample distances. Using the Wasserstein distance as the base measure, we reformulate the loss minimization as optimal piecewise linearization of quantile functions. We solve this optimization via stepwise algorithms and differential evolution. We also formulate semi‐supervised approaches where some thresholds are predefined based on scientific rationale. Applications to CGM datasets from diverse populations, including individuals with type 1 diabetes, type 2 diabetes, and normal glycemic control, demonstrate that data‐driven thresholds vary by population, improve discriminative power, and yield stronger associations with clinical variables over fixed thresholds.

Subjects

MeSH terms (MEDLINE)

Wearable Electronic DevicesHumansContinuous Glucose MonitoringAlgorithmsDiabetes Mellitus, Type 1Blood GlucoseActigraphyBlood Glucose Self-MonitoringLinear Models

Author keywords

Wasserstein distanceamalgamationcontinuous glucose monitoring (CGM)histogramtime‐in‐range (TIR)

Substances

Blood Glucose

Authors and institutions

  • Department of Biostatistics, University of Michigan, Ann Arbor, Michigan, USA.

ORCID profiles: Junyoung Park, Irina Gaynanova

Funding

  • NIH HHS
  • National Institutes of Health

Cite

APA

Park, J., Kok, N., & Gaynanova, I. (2026). Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions. Statistics in Medicine, 45(15-17). https://doi.org/10.1002/sim.70646

Vancouver

Park J, Kok N, Gaynanova I. Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions. Statistics in Medicine. 2026;45(15-17). doi:10.1002/sim.70646

BibTeX
@article{Park2026,
  author = {Park, Junyoung and Kok, Neo and Gaynanova, Irina},
  title = {Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions},
  journal = {Statistics in Medicine},
  year = {2026},
  volume = {45},
  number = {15-17},
  doi = {10.1002/sim.70646}
}
Start for free →