EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions

Junyoung Park iD, Neo Kok, Irina Gaynanova iD

Statistics in Medicine · 2026-07 · 45 (15-17)

DOI: 10.1002/sim.70646 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Statistics in Medicine, online erschienen am 30.06.2026. Verfasst von Junyoung Park und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biostatistics, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable devices, such as actigraphy monitors and continuous glucose monitors (CGMs), capture high‐frequency data, which are often summarized by the percentages of time spent within fixed thresholds. For example, actigraphy data are categorized into sedentary, light, and moderate‐to‐vigorous activity, while CGM data are divided into hypoglycemia, normoglycemia, and hyperglycemia based on a standard glucose range of 70–180 mg/dL. Although scientific and clinical guidelines inform the choice of thresholds, it remains unclear whether this choice is optimal and whether the same thresholds should be applied across different populations. In this work, we define threshold optimality with loss functions that quantify discrepancies between the full empirical distributions of wearable device measurements and their discretizations based on specific thresholds. We introduce two loss functions: one that aims to accurately reconstruct the original distributions and another that preserves the pairwise sample distances. Using the Wasserstein distance as the base measure, we reformulate the loss minimization as optimal piecewise linearization of quantile functions. We solve this optimization via stepwise algorithms and differential evolution. We also formulate semi‐supervised approaches where some thresholds are predefined based on scientific rationale. Applications to CGM datasets from diverse populations, including individuals with type 1 diabetes, type 2 diabetes, and normal glycemic control, demonstrate that data‐driven thresholds vary by population, improve discriminative power, and yield stronger associations with clinical variables over fixed thresholds.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesHumansContinuous Glucose MonitoringAlgorithmsDiabetes Mellitus, Type 1Blood GlucoseActigraphyBlood Glucose Self-MonitoringLinear Models

Stichwörter der Autor:innen

Wasserstein distanceamalgamationcontinuous glucose monitoring (CGM)histogramtime‐in‐range (TIR)

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • Department of Biostatistics, University of Michigan, Ann Arbor, Michigan, USA.

ORCID-Profile: Junyoung Park, Irina Gaynanova

Förderung

  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Park, J., Kok, N., & Gaynanova, I. (2026). Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions. Statistics in Medicine, 45(15-17). https://doi.org/10.1002/sim.70646

Vancouver

Park J, Kok N, Gaynanova I. Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions. Statistics in Medicine. 2026;45(15-17). doi:10.1002/sim.70646

BibTeX
@article{Park2026,
  author = {Park, Junyoung and Kok, Neo and Gaynanova, Irina},
  title = {Beyond Fixed Thresholds: Optimizing Summaries of Wearable Device Data via Piecewise Linearization of Quantile Functions},
  journal = {Statistics in Medicine},
  year = {2026},
  volume = {45},
  number = {15-17},
  doi = {10.1002/sim.70646}
}
Kostenlos starten →