EUVIMEDEUVIMED entdecken
Crossref

Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study

Hüseyin Sinan Topçuoğlu, Salih Düzgün, Firdevs Akpek, Gamze Topçuoğlu

Scanning · 2016-11 · 38 (6) · 585-590

DOI: 10.1002/sca.21304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Scanning, online erschienen am 21.01.2016. Verfasst von Hüseyin Sinan Topçuoğlu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Dentistry, Department of Endodontics, Erciyes University, Kayseri, Turkey. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluated the effect of creating a glide path and apical preparation size on the incidence of apical cracks during canal preparation in mandibular molar teeth with curved canals. One hundred and forty extracted teeth were used. The teeth were randomly assigned to one control group or six experimental groups (n = 20 per group) for canal preparation. No preparation was performed on teeth in the control group. In three of the six experimental groups, a glide path was not created; a glide path was created on the curved mesial canals of all teeth in the remaining three experimental groups. All teeth in experimental groups were then instrumented with the following systems: Reciproc, WaveOne (WO), and ProTaper Next (PTN). Digital images of the apical root surfaces of these teeth were recorded before preparation, after instrumentation with size 25 files, and after instrumentation with size 40 files. The images were then inspected for the presence of any new apical cracks and propagation. There was no significant difference between the experimental groups during canal preparation using size 25 files (p > 0.05). Reciproc and WO caused more new apical cracks than did PTN during canal preparation using size 40 files (p < 0.05). However, canal preparation using size 40 files did not cause propagation of existing cracks (p > 0.05). Performing a glide path prior to canal preparation did not change the incidence of apical crack during preparation. Additionally, increasing apical preparation size may increase the incidence of apical crack during canal preparation. SCANNING 38:585–590, 2016. © 2016 Wiley Periodicals, Inc.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Pulp CavityHumansMicroscopyMolarNickelRoot Canal PreparationTitaniumTooth Apex

Stichwörter der Autor:innen

dentistrymicroanalysis

Substanzen

NickelTitanium

Autor:innen und Institutionen

  • Faculty of Dentistry, Department of Endodontics, Erciyes University, Kayseri, Turkey.
  • Faculty of Dentistry, Department of Pedodontics, Erciyes University, Kayseri, Turkey.

Zitieren

APA

Topçuoğlu, H. S., Düzgün, S., Akpek, F., & Topçuoğlu, G. (2016). Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study. Scanning, 38(6), 585-590. https://doi.org/10.1002/sca.21304

Vancouver

Topçuoğlu HS, Düzgün S, Akpek F, Topçuoğlu G. Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study. Scanning. 2016;38(6):585-590. doi:10.1002/sca.21304

BibTeX
@article{Topuolu2016,
  author = {Topçuoğlu, Hüseyin Sinan and Düzgün, Salih and Akpek, Firdevs and Topçuoğlu, Gamze},
  title = {Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: A stereomicroscope study},
  journal = {Scanning},
  year = {2016},
  volume = {38},
  number = {6},
  pages = {585--590},
  doi = {10.1002/sca.21304}
}
Kostenlos starten →