EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluating In Vitro Performance of a Novel Stainless Steel Rotary System (Gentlefile) Based on Debris Extrusion and Instrumentation Time

Ahmad Nouroloyouni iD, Fatemeh Safavi Hir iD, Robab Farhang iD, Sara Noorolouny iD, Amin Salem Milani iD, Rashin Alyali iD

BioMed Research International · 2023

DOI: 10.1155/2023/9945236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BioMed Research International, 2023. Verfasst von Ahmad Nouroloyouni und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, School of Dentistry, Ardabil University of Medical Science, Ardabil, Iran. Hauptthemen laut MEDLINE: Titanium, Nickel. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The new Gentlefile (GF) system, made of stainless steel and developed by MedicNRG in Kibbutz Afikim, Israel, claims to have advantages over traditional nickel‐titanium files. However, research has shown that nickel‐titanium files are mechanically superior due to their increased flexibility, cutting efficiency, and ability to maintain canal anatomy with less risk of procedural errors. This study compared the amount of debris extrusion and the time required for root canal instrumentation using GF versus the nickel‐titanium ProTaper Universal (PTU) system and a manual step‐back (MSB) stainless steel technique. This in vitro experimental study utilized 66 extracted human single‐canal mandibular premolars with mature apices and root curvature of less than 10 degrees. The teeth were randomly divided into three groups ( n = 22) and standardized for working length before being placed in preweighed vials. Group 1 was instrumented with PTU, Group 2 with GF, and Group 3 with the MSB technique. Extruded debris was collected in the vials, dried in an incubator, and weighed using the same scale. The change in weight indicates the debris amount. Instrumentation time was recorded using a stopwatch. The normal distribution of data was assessed using the Kolmogorov‐Smirnov test. The groups were then compared regarding the amount of extruded debris and instrumentation time using the Kruskal‐Wallis test and one‐way ANOVA, followed by the Games‐Howell test, respectively (alpha = 0.05). No significant difference in apical debris extrusion was found among the three groups ( P > 0.05). However, a significant difference in instrumentation time was detected between the groups ( P < 0.05). MSB instrumentation took significantly longer than both the PTU ( P = 0.001) and GF ( P = 0.001) systems. The GF system did not demonstrate reduced apical debris extrusion or faster instrumentation time compared to PTU. MSB had the longest instrumentation time compared to the other techniques.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumNickelHumansStainless SteelRoot Canal PreparationTooth ApexDental Pulp CavityAlloys

Substanzen

TitaniumNickelStainless Steeltitanium nickelidenitinolAlloys

Autor:innen und Institutionen

  • Department of Endodontics, School of Dentistry, Ardabil University of Medical Science, Ardabil, Iran.
  • Department of Pediatric Dentistry, School of Dentistry, Ardabil University of Medical Science, Ardabil, Iran.
  • Department of Endodontics, School of Dentistry, Tabriz University of Medical Science, Tabriz, Iran.
  • Department of Dentistry, Guilan University of Medical Sciences, Rasht, Iran.

ORCID-Profile: Ahmad Nouroloyouni, Fatemeh Safavi Hir, Robab Farhang, Sara Noorolouny, Amin Salem Milani, Rashin Alyali

Zitieren

APA

Nouroloyouni, A., Safavi Hir, F., Farhang, R., Noorolouny, S., Salem Milani, A., & Alyali, R. (2023). Evaluating In Vitro Performance of a Novel Stainless Steel Rotary System (Gentlefile) Based on Debris Extrusion and Instrumentation Time. BioMed Research International. https://doi.org/10.1155/2023/9945236

Vancouver

Nouroloyouni A, Safavi Hir F, Farhang R, Noorolouny S, Salem Milani A, Alyali R. Evaluating In Vitro Performance of a Novel Stainless Steel Rotary System (Gentlefile) Based on Debris Extrusion and Instrumentation Time. BioMed Research International. 2023. doi:10.1155/2023/9945236

BibTeX
@article{Nouroloyouni2023,
  author = {Nouroloyouni, Ahmad and Safavi Hir, Fatemeh and Farhang, Robab and Noorolouny, Sara and Salem Milani, Amin and Alyali, Rashin},
  title = {Evaluating In Vitro Performance of a Novel Stainless Steel Rotary System (Gentlefile) Based on Debris Extrusion and Instrumentation Time},
  journal = {BioMed Research International},
  year = {2023},
  doi = {10.1155/2023/9945236}
}
Kostenlos starten →