Concurrent Oximetry and Transcutaneous Carbon Dioxide Monitoring to Screen for Paediatric Obstructive Sleep Apnoea

Felicity Cheng, Helen Vlachos‐Mayer, Karen A. Waters

Respirology · 2026-11-20

DOI: 10.1002/resp.70336 ↗

At a glance

Journal article in Respirology, published online on 2026-11-20. Written by Felicity Cheng and 2 co-authors. 20 references.

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background and Objective Obstructive sleep apnoea (OSA) diagnosis requires polysomnography (PSG) which can be difficult to access due to wait times. Concurrent oximetry and transcutaneous carbon dioxide (TcCO 2 ) monitoring is used in our sleep unit to triage patients, but its diagnostic utility has not been formally evaluated. The objective of the study was to assess whether adding TcCO 2 to overnight oximetry improves screening accuracy for paediatric OSA when compared to a full PSG scored according to the American Academy of Sleep Medicine (AASM) guidelines.

Methods

Retrospective analysis of 172 consecutive overnight PSGs performed at the Children's Hospital at Westmead. Three independent sleep consultants scored deidentified oximetry traces (Phase 1), then the same traces with concurrent TcCO 2 (Phase 2). Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with 95% Wilson confidence intervals were calculated for the senior clinician's impression against the PSG‐based AASM diagnosis. Univariate logistic regression identified individual predictors of OSA.

Results

The diagnosis of OSA within the study cohort was 77.3% (133/172). Oximetry alone yielded sensitivity 0.865 (95% CI 0.796–0.913) and NPV 0.514 (0.359–0.666). Adding TcCO 2 without a structured scoring framework reduced sensitivity to 0.629 (0.544–0.706) and NPV to 0.310 (0.214–0.425), with non‐overlapping confidence intervals. The strongest predictor of OSA was concurrent carbon dioxide (CO 2 ) retention with oxygen (O 2 ) desaturation (OR 9.83, 95% CI 2.88–33.54). Overall inter‐rater agreement was poor (weighted κ = 0.13), which reflects lack of clearly defined diagnostic criteria. Concurrent CO 2 and O 2 events, CO 2 rise above baseline of 5–9 mmHg, and episodic CO 2 retention are the strongest identifiable predictors of OSA.

Conclusions

TcCO 2 adds extra information to oximetry traces. However, without an established scoring system, adding CO 2 traces reduces sensitivity of diagnosing OSA. Further research needs to be conducted in developing and validating a scoring system to interpret CO 2 traces.

Cite

APA

Cheng, F., Vlachos‐Mayer, H., & Waters, K. A. (2026). Concurrent Oximetry and Transcutaneous Carbon Dioxide Monitoring to Screen for Paediatric Obstructive Sleep Apnoea. Respirology. https://doi.org/10.1002/resp.70336

Vancouver

Cheng F, Vlachos‐Mayer H, Waters KA. Concurrent Oximetry and Transcutaneous Carbon Dioxide Monitoring to Screen for Paediatric Obstructive Sleep Apnoea. Respirology. 2026. doi:10.1002/resp.70336

BibTeX
@article{Cheng2026,
  author = {Cheng, Felicity and Vlachos‐Mayer, Helen and Waters, Karen A.},
  title = {Concurrent Oximetry and Transcutaneous Carbon Dioxide Monitoring to Screen for Paediatric Obstructive Sleep Apnoea},