Safety and Efficacy of Direct Cryobiopsy Specimen Retrieval Through the 3.0‐mm Working Channel of a Therapeutic Bronchoscope Using a 1.1‐mm Cryoprobe: A Multicentre Prospective Observational Study
Respirology · 16.09.2026
DOI: 10.1002/resp.70314 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respirology, online erschienen am 16.09.2026. Verfasst von Yuki Takigawa und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Respiratory Medicine, NHO Okayama Medical Center, Okayama, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background and Objective Cryobiopsy using a 1.1‐mm cryoprobe through a therapeutic bronchoscope with a 3.0‐mm working channel permits en bloc retrieval of the cryoprobe and guide sheath while the bronchoscope remains wedged in the target bronchus, potentially facilitating immediate haemostatic control. This study investigated the safety and efficacy of this technique.
Methods
This prospective observational study enrolled patients with peripheral pulmonary lesions suspected of lung cancer who underwent forceps biopsy (FB), followed by cryobiopsy using a 1.1‐mm cryoprobe through a therapeutic bronchoscope with a 3.0‐mm working channel. The primary endpoint was procedural safety, as assessed by bleeding grade. The secondary endpoints included procedure‐related complications, diagnostic yield, specimen size, procedural success rate, and biomarker analysis success rate.
Results
Of 100 enrolled patients, 96 were included in the analysis, and 84 underwent cryobiopsy. Bleeding severity was Grade 0 in 35.4% (34 of 96), Grade 1 in 41.7% (40 of 96), Grade 2 in 8.3% (8 of 96), and Grade 3 in 2.1% (2 of 96) of patients. Diagnostic yields were 77.0% (74 of 96) for FB and 79.1% (76 of 96) for cryobiopsy, with an overall yield of 87.5% (84 of 96). Cryobiopsy provided the sole diagnosis in 10 patients and yielded significantly larger specimens than FB (7.06 vs. 2.46 mm 2 ; p < 0.001). The success rate of multiplex genetic testing was 95.8% for cryobiopsy (23 of 24).
Conclusion
Direct retrieval of cryobiopsy specimens through the working channel of a therapeutic bronchoscope is safe and feasible, yielding larger specimens with complementary diagnostic value.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Respiratory Medicine, NHO Okayama Medical Center, Okayama, Japan.
- Department of Respiratory Medicine, NHO Nagoya Medical Center, Nagoya, Japan.
ORCID-Profile: Yuki Takigawa, Suzuka Matsuoka, Atsushi Torii, Jun Nishimura, Yuka Shinohara, Masahiro Sano, Yoshihito Kogure, Keiichi Fujiwara
Zitieren
APA
Takigawa, Y., Oki, M., Sato, K., Matsuoka, S., Torii, A., Nishimura, J., Shinohara, Y., Watanabe, H., Sano, M., Kudo, K., Sato, A., Kogure, Y., Fujiwara, K., & Shibayama, T. (2026). Safety and Efficacy of Direct Cryobiopsy Specimen Retrieval Through the 3.0‐mm Working Channel of a Therapeutic Bronchoscope Using a 1.1‐mm Cryoprobe: A Multicentre Prospective Observational Study. Respirology. https://doi.org/10.1002/resp.70314
Vancouver
Takigawa Y, Oki M, Sato K, Matsuoka S, Torii A, Nishimura J, et al. Safety and Efficacy of Direct Cryobiopsy Specimen Retrieval Through the 3.0‐mm Working Channel of a Therapeutic Bronchoscope Using a 1.1‐mm Cryoprobe: A Multicentre Prospective Observational Study. Respirology. 2026. doi:10.1002/resp.70314
BibTeX
@article{Takigawa2026,
author = {Takigawa, Yuki and Oki, Masahide and Sato, Ken and Matsuoka, Suzuka and Torii, Atsushi and Nishimura, Jun and Shinohara, Yuka and Watanabe, Hiromi and Sano, Masahiro and Kudo, Kenichiro and Sato, Akiko and Kogure, Yoshihito and Fujiwara, Keiichi and Shibayama, Takuo},
title = {Safety and Efficacy of Direct Cryobiopsy Specimen Retrieval Through the 3.0‐mm Working Channel of a Therapeutic Bronchoscope Using a 1.1‐mm Cryoprobe: A Multicentre Prospective Observational Study},
journal = {Respirology},
year = {2026},
doi = {10.1002/resp.70314}
}
EUVIMED