EUVIMEDEUVIMED entdecken
Crossref

Design of a Continuum Surgical Robotic System for Bimanual Endoscopic Submucosal Dissection

Haiyan Hu, Heng Zhang iD, Zhenhao Chen, Haojie Tian, Shumei Yu, Yong Jiang

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025

DOI: 10.1002/rcs.70127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Haiyan Hu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Endoscopic Mucosal Resection. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: National Key Research and Development Program of China, project of the Jiangsu Key Laboratory of Advanced Robotics.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Digestive tract cancers are among the most common malignancies worldwide, and early diagnosis greatly improves patient prognosis. For instance, colorectal cancer has a 90% 5‐year survival rate at early stages. Endoscopic Submucosal Dissection (ESD) is the standard treatment, but traditional flexible endoscopes pose operational and visual challenges.

Methods

This paper proposes a dual‐continuum robotic surgical system based on a cascaded vertebrae design. Kinematic and frictional modelling analyses were conducted to ensure stable operation of the surgical robotic system on a commercial endoscope. In addition, a teleoperation system was developed to enable bimanual ESD procedures.

Results

Experimental validation confirmed the system's workspace, stiffness, hysteresis optimisation, and teleoperation accuracy. In an ex vivo ESD procedure performed on a porcine stomach, the system successfully resected a lesion with a diameter of 20 mm.

Conclusion

This continuum robotic system demonstrates strong clinical potential to enhance ESD performance and reduce procedural difficulty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresEndoscopic Mucosal ResectionSwineAnimalsEquipment DesignHumansBiomechanical PhenomenaStomach

Stichwörter der Autor:innen

continuum robotendoscopic submucosal dissection (ESD)feedforward compensationkinematic modellingsurgical robot system

Autor:innen und Institutionen

  • School of Mechanical and Electrical Engineering, Soochow University, Suzhou, China.
  • School of Agricultural Engineering, Jiangsu University, Zhenjiang, China.

ORCID-Profile: Heng Zhang

Förderung

  • National Key Research and Development Program of China
  • project of the Jiangsu Key Laboratory of Advanced Robotics

Zitieren

APA

Hu, H., Zhang, H., Chen, Z., Tian, H., Yu, S., & Jiang, Y. (2025). Design of a Continuum Surgical Robotic System for Bimanual Endoscopic Submucosal Dissection. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70127

Vancouver

Hu H, Zhang H, Chen Z, Tian H, Yu S, Jiang Y. Design of a Continuum Surgical Robotic System for Bimanual Endoscopic Submucosal Dissection. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70127

BibTeX
@article{Hu2025,
  author = {Hu, Haiyan and Zhang, Heng and Chen, Zhenhao and Tian, Haojie and Yu, Shumei and Jiang, Yong},
  title = {Design of a Continuum Surgical Robotic System for Bimanual Endoscopic Submucosal Dissection},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70127}
}
Kostenlos starten →