EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Measuring Abdominal Skin‐Surface Distances Using Photos for Perforator Mapping Analysis—A Validation Study on 3D‐Printed DIEP‐Flap Models

Fabian N Necker iD, David J Cholok iD, Marc J Fischer, Kyle Gifford iD, Chris Le Castillo iD, Michael Scholz iD, Michael Januszyk iD, Christoph W Leuze iD, Bruce L Daniel iD, Arash Momeni iD

The International Journal of Medical Robotics and Computer Assisted Surgery · 2025

DOI: 10.1002/rcs.70108 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift The International Journal of Medical Robotics and Computer Assisted Surgery, 2025. Verfasst von Fabian N Necker und 9 weiteren Autor:innen. Beteiligte Einrichtung: Digital Anatomy Lab, Faculty of Medicine, Institute of Functional and Clinical Anatomy, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Erla…. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Skin, Perforator Flap, Abdomen. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bayrisches Forschungsinstitut für Digitale Transformation, Bayerisch-Kalifornischen Hochschulzentrum.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

We present a novel method for accurately measuring skin‐surface distances using standard smartphone photos and Photoshop, validated on 3D‐printed DIEP‐flap models and on calibration grid‐patterns. Materials and Methods Distance measurements are acquired in Photoshop in a calibration plane between dots on a grid‐pattern as well as between perforators on photos of 3D‐printed models and compared against ground‐truth. Margins of errors are calculated from fitted linear models.

Results

Submillimeter accuracy can be achieved within errors of ±0.45 mm (80% probability) and ±0.8 mm (95% probability) for measuring distances on the dot‐grid. On the 3D‐printed DIEP‐models, distance measurements are accurate within ±1.75 mm (80% probability) and ±3.1 mm (95% probability).

Conclusions

We introduce a simple yet highly accurate technique to measure skin‐surface distances using normal photos. Depending on the scenario, submillimeter or conservatively very low millimetre errors can be achieved, sufficiently accurate for clinical use, whilst maintaining topographic relationships of the measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalSkinPerforator FlapAbdomenHumansCalibrationReproducibility of ResultsModels, AnatomicPhotographySmartphone

Stichwörter der Autor:innen

3D‐printed DIEP‐flapsaccuracy validationperforator locationperforator mappingperspective‐corrected photographsskin‐surface measurements

Autor:innen und Institutionen

  • Digital Anatomy Lab, Faculty of Medicine, Institute of Functional and Clinical Anatomy, Friedrich-Alexander Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.
  • Department of Radiology, Stanford IMMERS (Incubator for Medical Mixed and Extended Reality at Stanford), Stanford University School of Medicine, Palo Alto, California, USA.
  • Division of Plastic and Reconstructive Surgery, Stanford University School of Medicine, Palo Alto, California, USA.
  • Department of Radiology, 3D and Quantitative Imaging, Stanford University School of Medicine, Stanford, California, USA.

ORCID-Profile: Fabian N Necker, David J Cholok, Kyle Gifford, Chris Le Castillo, Michael Scholz, Michael Januszyk, Christoph W Leuze, Bruce L Daniel, Arash Momeni

Förderung

  • Bayrisches Forschungsinstitut für Digitale Transformation
  • Bayerisch-Kalifornischen Hochschulzentrum

Zitieren

APA

Necker, F. N., Cholok, D. J., Fischer, M. J., Gifford, K., Le Castillo, C., Scholz, M., Januszyk, M., Leuze, C. W., Daniel, B. L., & Momeni, A. (2025). Measuring Abdominal Skin‐Surface Distances Using Photos for Perforator Mapping Analysis—A Validation Study on 3D‐Printed DIEP‐Flap Models. The International Journal of Medical Robotics and Computer Assisted Surgery. https://doi.org/10.1002/rcs.70108

Vancouver

Necker FN, Cholok DJ, Fischer MJ, Gifford K, Le Castillo C, Scholz M, et al. Measuring Abdominal Skin‐Surface Distances Using Photos for Perforator Mapping Analysis—A Validation Study on 3D‐Printed DIEP‐Flap Models. The International Journal of Medical Robotics and Computer Assisted Surgery. 2025. doi:10.1002/rcs.70108

BibTeX
@article{Necker2025,
  author = {Necker, Fabian N and Cholok, David J and Fischer, Marc J and Gifford, Kyle and Le Castillo, Chris and Scholz, Michael and Januszyk, Michael and Leuze, Christoph W and Daniel, Bruce L and Momeni, Arash},
  title = {Measuring Abdominal Skin‐Surface Distances Using Photos for Perforator Mapping Analysis—A Validation Study on 3D‐Printed DIEP‐Flap Models},
  journal = {The International Journal of Medical Robotics and Computer Assisted Surgery},
  year = {2025},
  doi = {10.1002/rcs.70108}
}
Kostenlos starten →