PelviSound L—Real‐time intraoperative sonographic assessment of pelvic sentinel lymph nodes using a drop‐in probe in endometrial and cervical cancer during minimally invasive surgery: A single‐center pilot feasibility study in 20 patients
International Journal of Gynecology & Obstetrics · 2026
DOI: 10.1002/ijgo.70838 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Gynecology & Obstetrics, 2026. Verfasst von Sascha Hoffmann und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Women's Health, University Women's Hospital Tübingen, Tübingen, Germany. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Endometrial Neoplasms, Sentinel Lymph Node, Sentinel Lymph Node Biopsy. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
Sentinel lymph node biopsy (SLNB) is considered an essential step in the surgical management of endometrial and cervical cancers as it has led to a reduction in the need for full pelvic lymphadenectomy. This proof‐of‐concept study aimed to evaluate the feasibility and diagnostic performance of intraoperative sonographic assessment of sentinel lymph nodes (SLNs) during laparoscopic and robotic surgeries for endometrial and cervical cancers.
Methods
This was a prospective, single‐center, non‐interventional diagnostic feasibility study conducted between October 2023 and July 2024 at the University Women's Hospital, Tübingen, Germany, and registered at the German Clinical Trials Register (DRKS00032919). A total of 20 patients underwent intraoperative sonographic SLN evaluation using a sterile drop‐in ultrasound probe prior to resection. The assessment was based on the Vulvar International Tumor Analysis (VITA) criteria that includes parameters, such as lymph node shape, cortical thickening, vascularization, and echogenicity. Findings were correlated with histopathologic results to determine diagnostic accuracy. To assess the diagnostic accuracy of the sonographic criteria, a receiver operating characteristic (ROC) analysis was conducted, focusing on sensitivity and specificity with respect to lesion dignity classification (benign vs malignant).
Results
Among the 25 initially prepped patients, 20 successfully underwent intraoperative sonographic SLN evaluation, while five were excluded due to logistical issues or consent withdrawal. A total of 49 SLNs were analyzed, and the analysis included histopathologic confirmation. The sonographic assessment demonstrated perfect sensitivity and specificity of 1.0 as reflected by the area under the ROC curve (AUC = 1.0). No adverse events were reported.
Conclusion
The study confirms that intraoperative sonographic evaluation of SLNs in minimally invasive gynecologic oncology surgeries is feasible, safe, and highly accurate. This technique may serve as a valuable adjunct to current SLNB protocols and lead to a potential reduction in the need for extensive lymphadenectomy while concurrently maintaining diagnostic reliability. Further research using larger cohorts is warranted to validate these findings and assess broader clinical applicability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Women's Health, University Women's Hospital Tübingen, Tübingen, Germany.
ORCID-Profile: Sascha Hoffmann
Zitieren
APA
Hoffmann, S., Trif, L., Krämer, B., Neis, F., Wallwiener, D., Brucker, S. Y., Hoopmann, M., & Hahn, M. (2026). PelviSound L—Real‐time intraoperative sonographic assessment of pelvic sentinel lymph nodes using a drop‐in probe in endometrial and cervical cancer during minimally invasive surgery: A single‐center pilot feasibility study in 20 patients. International Journal of Gynecology & Obstetrics. https://doi.org/10.1002/ijgo.70838
Vancouver
Hoffmann S, Trif L, Krämer B, Neis F, Wallwiener D, Brucker SY, et al. PelviSound L—Real‐time intraoperative sonographic assessment of pelvic sentinel lymph nodes using a drop‐in probe in endometrial and cervical cancer during minimally invasive surgery: A single‐center pilot feasibility study in 20 patients. International Journal of Gynecology & Obstetrics. 2026. doi:10.1002/ijgo.70838
BibTeX
@article{Hoffmann2026,
author = {Hoffmann, Sascha and Trif, Laura and Krämer, Bernhard and Neis, Felix and Wallwiener, Diethelm and Brucker, Sara Y and Hoopmann, Markus and Hahn, Markus},
title = {PelviSound L—Real‐time intraoperative sonographic assessment of pelvic sentinel lymph nodes using a drop‐in probe in endometrial and cervical cancer during minimally invasive surgery: A single‐center pilot feasibility study in 20 patients},
journal = {International Journal of Gynecology & Obstetrics},
year = {2026},
doi = {10.1002/ijgo.70838}
}
EUVIMED