EUVIMEDEUVIMED entdecken
Open Access

Experimental assessment of elemental analyzer isotope ratio mass spectrometry normalization methodologies for environmental stable isotopes

Sawyer Balint iD, Morgan Schwartz iD, Drew N Fowler, Stella Linnekogel, Sáde Cromratie Clemons, Laura K Burkemper

Rapid Communications in Mass Spectrometry · 2024-09 · 38 (17)

DOI: 10.1002/rcm.9837 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 24.06.2024. Verfasst von Sawyer Balint und 5 weiteren Autor:innen. Beteiligte Einrichtung: ORISE Participant, U.S. EPA Atlantic Coastal Environmental Sciences Division, Narragansett, Rhode Island, United States. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural EPA, US Environmental Protection Agency Office of Research and Development, Oak Ridge Institute for Science and Education.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

In stable isotope mass spectrometry, isotope delta values are normalized to internationally recognized reference scales using a combination of certified and in‐house isotope reference materials. Numerous techniques exist for performing this normalization, but these methodologies need to be experimentally assessed to compare their effect on reproducibility of isotope results.

Methods

We tested normalization methods by the number of reference materials used, their matrix, their isotope range, and whether normalization required extrapolating beyond the isotope range. We analyzed eight commercially available isotope reference materials on a ThermoFinnigan Delta‐V isotope ratio mass spectrometer (IRMS) and an Elementar VisION IRMS for nitrogen and carbon isotope composition via solid combustion with an elemental analyzer and computed every possible isotope normalization (n = 612). Additionally, we assessed how sample matrix affected linearity effects on both instruments using five in‐house reference materials.

Results

Normalizations exhibited the best performance when the reference materials spanning an isotope range of at least 20‰ were matrix matched with the samples and did not require extrapolation beyond the calibration curve. When these conditions were not met, the number of reference materials used had a significant effect on accuracy, with normalizations composed of two reference materials exhibiting particularly inconsistent performance at isotope ranges below 20‰. Linearity effects were found to exceed instrument precision by two orders of magnitude irrespective of matrix type and were not predicted by working gas diagnostics.

Conclusions

Interlaboratory comparability of isotope results is improved when operators of elemental analyzer isotope ratio mass spectrometry (EAIRMS) systems select reference materials spanning an isotope range of at least 20‰. Additionally, using three or more isotopic reference materials, avoiding extrapolation beyond the range of the normalization curve, and matching the matrix of the reference materials to the samples improve normalizations.

Autor:innen und Institutionen

  • ORISE Participant, U.S. EPA Atlantic Coastal Environmental Sciences Division, Narragansett, Rhode Island, United States.
  • U.S. EPA Atlantic Coastal Environmental Sciences Division, Narragansett, Rhode Island, United States.
  • Louisiana Cooperative Fish and Wildlife Research Unit, U.S. Geological Survey, Baton Rouge, Louisiana, United States.
  • UK Centre for Ecology & Hydrology Lancaster, Lancaster, UK.
  • Department of Geography, University of Colorado Boulder, Boulder, Colorado, United States.
  • Center for Stable Isotopes, University of New Mexico, Albuquerque, New Mexico, United States.

ORCID-Profile: Sawyer Balint, Morgan Schwartz

Förderung

  • Intramural EPA
  • US Environmental Protection Agency Office of Research and Development
  • Oak Ridge Institute for Science and Education
  • U.S. Environmental Protection Agency

Zitieren

APA

Balint, S., Schwartz, M., Fowler, D. N., Linnekogel, S., Clemons, S. C., & Burkemper, L. K. (2024). Experimental assessment of elemental analyzer isotope ratio mass spectrometry normalization methodologies for environmental stable isotopes. Rapid Communications in Mass Spectrometry, 38(17). https://doi.org/10.1002/rcm.9837

Vancouver

Balint S, Schwartz M, Fowler DN, Linnekogel S, Clemons SC, Burkemper LK. Experimental assessment of elemental analyzer isotope ratio mass spectrometry normalization methodologies for environmental stable isotopes. Rapid Communications in Mass Spectrometry. 2024;38(17). doi:10.1002/rcm.9837

BibTeX
@article{Balint2024,
  author = {Balint, Sawyer and Schwartz, Morgan and Fowler, Drew N and Linnekogel, Stella and Clemons, Sáde Cromratie and Burkemper, Laura K},
  title = {Experimental assessment of elemental analyzer isotope ratio mass spectrometry normalization methodologies for environmental stable isotopes},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2024},
  volume = {38},
  number = {17},
  doi = {10.1002/rcm.9837}
}
Kostenlos starten →