EUVIMEDEUVIMED entdecken
Crossref

User‐friendly relative quantification procedure for gas chromatography/mass spectrometry–based plasma metabolome analysis

Shin Nishiumi iD, Tomonori Yokoyama, Noriyuki Ojima

Rapid Communications in Mass Spectrometry · 2024

DOI: 10.1002/rcm.9683 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2024. Verfasst von Shin Nishiumi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Omics Medicine, Hyogo Medical University, Nishinomiya, Japan. Hauptthemen laut MEDLINE: Metabolome, Plasma. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: Practical Research Project for Rare/Intractable Disease run by the Japan Agency for Medical Research and Development, research fund provided by Shimadzu Co., Research Funds from the Kobe College Research Institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rationale

Recently, metabolome analysis has been applied to a variety of research fields, but differences between batches or facilities can cause discrepancies in the results of such analyses. To resolve these issues using comprehensive metabolome analysis, in which it is difficult to perform quantitative analyses of all detected metabolites, internal standard compounds are used to obtain relative metabolite levels. This study investigated gas chromatography/mass spectrometry–based plasma metabolome analysis methods that are superior to relative quantification using internal standard compounds.

Methods

In experiment I, four analyses were performed under different analytical conditions at one facility, and then the data from the four analyses were compared. In experiment II, the same samples were analyzed at three facilities, and then the data from the three facilities were compared.

Results

Regarding the relative values obtained through comparisons with the internal standard compound, differences in the analytical results were observed among the four analytical conditions in experiment I and among the three facilities in experiment II, and the differences observed among the three facilities (experiment II) were larger. When correction was performed using plasma as a quality control, which is the procedure suggested in this study, these differences were markedly ameliorated.

Conclusion

The suggested procedure involves the analysis of a plasma standard as a quality control for each batch and the calculation of relative target plasma to quality‐control plasma values for each metabolite. This is an easy and low‐cost method and could be readily employed by researchers during comprehensive plasma metabolome analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetabolomePlasmaGas Chromatography-Mass SpectrometryQuality ControlMetabolomics

Autor:innen und Institutionen

  • Department of Omics Medicine, Hyogo Medical University, Nishinomiya, Japan.
  • Department of Biosphere Sciences, School of Human Sciences, Kobe College, Nishinomiya, Japan.
  • Analytical and Measuring Instruments Division, Shimadzu Corporation, Kyoto, Japan.

ORCID-Profile: Shin Nishiumi

Förderung

  • Practical Research Project for Rare/Intractable Disease run by the Japan Agency for Medical Research and Development
  • research fund provided by Shimadzu Co.
  • Research Funds from the Kobe College Research Institute
  • Research Funds from the School of Human Sciences, Kobe College
  • Japan Society for the Promotion of Science
  • Japan Agency for Medical Research and Development
  • Kobe College Research Institute
  • School of Human Sciences, Kobe College

Zitieren

APA

Nishiumi, S., Yokoyama, T., & Ojima, N. (2024). User‐friendly relative quantification procedure for gas chromatography/mass spectrometry–based plasma metabolome analysis. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9683

Vancouver

Nishiumi S, Yokoyama T, Ojima N. User‐friendly relative quantification procedure for gas chromatography/mass spectrometry–based plasma metabolome analysis. Rapid Communications in Mass Spectrometry. 2024. doi:10.1002/rcm.9683

BibTeX
@article{Nishiumi2024,
  author = {Nishiumi, Shin and Yokoyama, Tomonori and Ojima, Noriyuki},
  title = {User‐friendly relative quantification procedure for gas chromatography/mass spectrometry–based plasma metabolome analysis},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2024},
  doi = {10.1002/rcm.9683}
}
Kostenlos starten →