Development and Validation of Targeted Metabolomics Methods Using Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) for the Quantification of 235 Plasma Metabolites
Molecules · 05.02.2025 · 30 (3) · 706
DOI: 10.3390/molecules30030706 ↗Kurz gefasst
Fachartikel in der Zeitschrift Molecules, online erschienen am 05.02.2025. Verfasst von Kangkang Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Bioanalytics and Agro-Metabolomics, Department of Agricultural Sciences, BOKU University, 3430 Tulln, Austria. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Metabolomics, Metabolome, Plasma. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Christian Doppler Research Association, Austrian Competence Centre for Feed and Food Quality, Safety and Innovation, Lower Austrian Government.
Abstract (Originalsprache)
Plasma contains metabolites with diverse physicochemical properties, ranging from highly polar to highly apolar, and concentrations spanning at least nine orders of magnitude. Plasma metabolome analysis is valuable for monitoring health and evaluating medical interventions but is challenging due to the metabolome’s diversity and complexity. This study aims to develop and validate targeted LC-MS/MS methods for quantifying 235 mammalian metabolites from 17 compound classes in porcine plasma without prior derivatization. Utilizing reversed-phase and hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry, each analyte is identified and quantified using two selected reaction monitoring (SRM) transitions. Fast polarity switching and scheduled SRM enhance the metabolome coverage and throughput, enabling the analysis of one sample in about 40 min. A simple “dilute and shoot” sample preparation protocol was employed, with samples injected at two dilution levels to align metabolite concentrations within calibration curve ranges. Validation in porcine plasma included assessments of carryover, linearity, detection and quantification limits, repeatability and recovery. The method was further applied to plasma samples from various animal species, demonstrating its applicability to human and animal studies. This study establishes two robust LC-MS/MS methods for comprehensive porcine plasma metabolome quantification, advancing large-scale targeted metabolomics in biomedical research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Bioanalytics and Agro-Metabolomics, Department of Agricultural Sciences, BOKU University, 3430 Tulln, Austria.
- Christian Doppler Laboratory for Innovative Gut Health Concepts of Livestock, 1210 Vienna, Austria.
- Austrian Competence Centre for Feed and Food Quality, Safety and Innovation (FFoQSI), 3430 Tulln, Austria.
- Unit Nutritional Physiology, Department of Biomedical Sciences, University of Veterinary Medicine, Veterinaerplatz 1, 1210 Vienna, Austria.
ORCID-Profile: Kangkang Xu, Franz Berthiller, Barbara U Metzler-Zebeli, Heidi E Schwartz-Zimmermann
Förderung
- Christian Doppler Research Association
- Austrian Competence Centre for Feed and Food Quality, Safety and Innovation
- Lower Austrian Government
- European Regional Development Fund
- Austrian Federal Ministry for Digital and Economic Affairs
- Austrian National Foundation for Research, Technology and Development
- BIOMIN Holding GmbH
Zitieren
APA
Xu, K., Berthiller, F., Metzler-Zebeli, B. U., & Schwartz-Zimmermann, H. E. (2025). Development and Validation of Targeted Metabolomics Methods Using Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) for the Quantification of 235 Plasma Metabolites. Molecules, 30(3), 706. https://doi.org/10.3390/molecules30030706
Vancouver
Xu K, Berthiller F, Metzler-Zebeli BU, Schwartz-Zimmermann HE. Development and Validation of Targeted Metabolomics Methods Using Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) for the Quantification of 235 Plasma Metabolites. Molecules. 2025;30(3):706. doi:10.3390/molecules30030706
BibTeX
@article{Xu2025,
author = {Xu, Kangkang and Berthiller, Franz and Metzler-Zebeli, Barbara U and Schwartz-Zimmermann, Heidi E},
title = {Development and Validation of Targeted Metabolomics Methods Using Liquid Chromatography–Tandem Mass Spectrometry (LC-MS/MS) for the Quantification of 235 Plasma Metabolites},
journal = {Molecules},
year = {2025},
volume = {30},
number = {3},
pages = {706},
doi = {10.3390/molecules30030706}
}
EUVIMED