Journal article in Rapid Communications in Mass Spectrometry, 2023. Written by Yamin Liu and 3 co-authors. Institution: MOE Key Laboratory of Standardization of Chinese Medicines and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Ins…. Major MEDLINE topics: Renin-Angiotensin System, Tandem Mass Spectrometry. Cited 2 times so far (Crossref); 47 references. Funded by: National Natural Science Foundation of China, Program of Shanghai Municipal Health Commission.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

The renin–angiotensin system produces a series of biologically active angiotensin (Ang) peptides. These Ang peptides are the major regulators of blood pressure and Na homeostasis, and play a critical role in maintaining cardiovascular and fluid homeostasis. The concentration of Ang peptides in the body is at trace levels, making their detection and quantification a challenge. In this study, a rapid and sensitive analytical method using mass spectrometry coupled with ultrahigh‐performance liquid chromatography (UHPLC/MS) was developed to simultaneously quantify 14 Ang peptides.

Methods

UHPLC/MS was employed to quantify 14 Ang peptides in mouse and human plasma. An HSS T3 column (2.1 × 100 mm, 1.8 μm) with an HSS T3 precolumn and triple‐quadrupole mass spectrometer combined with an electrospray ionization source were utilized. Sample pretreatment involved a one‐step protein precipitation using methanol. The total analysis time was within 7.5 min and the target peptides were detected in positive ion mode and quantified by selected reaction monitoring mode.

Results

The method was validated for linearity, detection and quantification limits, precision, stability, recovery and matrix effect. The limits of detection of Ang II, Ang III, Ang‐(1–7), Ang‐(2–7), Ang‐(3–7), Ang‐(1–9), bradykinin, Asn 1 and Val 5 ‐Ang II are all less than 1 pg mL −1 , indicating high sensitivity. The intra‐day and inter‐day precision was within 15%, and the accuracy was between 85% and 115%. Meanwhile, the sample and reference solution were stable within 48 h, and the recovery and matrix effect met the quantitative requirements.

Conclusions

The method is currently reported to allow the largest number of Ang peptide species to be detected at one time. In addition, the proposed method offers a fast and reliable approach for comprehensive analysis of Ang metabolism in biological samples, facilitating research on the physiological and pathological states of cardiovascular, kidney and respiratory diseases.

Subjects

MeSH terms (MEDLINE)

Renin-Angiotensin SystemTandem Mass SpectrometryHumansMiceAnimalsChromatography, LiquidPeptidesKidneyChromatography, High Pressure Liquid

Substances

Peptides

Authors and institutions

  • MOE Key Laboratory of Standardization of Chinese Medicines and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional C…
  • Shanghai R&D Center for Standardization of Chinese Medicines, Shanghai, China.

ORCID profiles: Linnan Li

Funding

  • National Natural Science Foundation of China
  • Program of Shanghai Municipal Health Commission

Cite

APA

Liu, Y., Li, L., Wang, Z., & Yang, L. (2023). A comprehensive profiling of renin–angiotensin system in mouse and human plasma by a rapid quantitative analysis of 14 angiotensin peptides using ultrahigh‐performance liquid chromatography with tandem mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9637

Vancouver

Liu Y, Li L, Wang Z, Yang L. A comprehensive profiling of renin–angiotensin system in mouse and human plasma by a rapid quantitative analysis of 14 angiotensin peptides using ultrahigh‐performance liquid chromatography with tandem mass spectrometry. Rapid Communications in Mass Spectrometry. 2023. doi:10.1002/rcm.9637

BibTeX
@article{Liu2023,
  author = {Liu, Yamin and Li, Linnan and Wang, Zhengtao and Yang, Li},
  title = {A comprehensive profiling of renin–angiotensin system in mouse and human plasma by a rapid quantitative analysis of 14 angiotensin peptides using ultrahigh‐performance liquid chromatography with tandem mass spectrometry},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2023},
  doi = {10.1002/rcm.9637}
}
Start for free →