EUVIMEDEUVIMED entdecken
Crossref

A comprehensive profiling of renin–angiotensin system in mouse and human plasma by a rapid quantitative analysis of 14 angiotensin peptides using ultrahigh‐performance liquid chromatography with tandem mass spectrometry

Yamin Liu, Linnan Li iD, Zhengtao Wang, Li Yang

Rapid Communications in Mass Spectrometry · 2023

DOI: 10.1002/rcm.9637 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, 2023. Verfasst von Yamin Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: MOE Key Laboratory of Standardization of Chinese Medicines and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Ins…. Hauptthemen laut MEDLINE: Renin-Angiotensin System, Tandem Mass Spectrometry. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Program of Shanghai Municipal Health Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The renin–angiotensin system produces a series of biologically active angiotensin (Ang) peptides. These Ang peptides are the major regulators of blood pressure and Na homeostasis, and play a critical role in maintaining cardiovascular and fluid homeostasis. The concentration of Ang peptides in the body is at trace levels, making their detection and quantification a challenge. In this study, a rapid and sensitive analytical method using mass spectrometry coupled with ultrahigh‐performance liquid chromatography (UHPLC/MS) was developed to simultaneously quantify 14 Ang peptides.

Methods

UHPLC/MS was employed to quantify 14 Ang peptides in mouse and human plasma. An HSS T3 column (2.1 × 100 mm, 1.8 μm) with an HSS T3 precolumn and triple‐quadrupole mass spectrometer combined with an electrospray ionization source were utilized. Sample pretreatment involved a one‐step protein precipitation using methanol. The total analysis time was within 7.5 min and the target peptides were detected in positive ion mode and quantified by selected reaction monitoring mode.

Results

The method was validated for linearity, detection and quantification limits, precision, stability, recovery and matrix effect. The limits of detection of Ang II, Ang III, Ang‐(1–7), Ang‐(2–7), Ang‐(3–7), Ang‐(1–9), bradykinin, Asn 1 and Val 5 ‐Ang II are all less than 1 pg mL −1 , indicating high sensitivity. The intra‐day and inter‐day precision was within 15%, and the accuracy was between 85% and 115%. Meanwhile, the sample and reference solution were stable within 48 h, and the recovery and matrix effect met the quantitative requirements.

Conclusions

The method is currently reported to allow the largest number of Ang peptide species to be detected at one time. In addition, the proposed method offers a fast and reliable approach for comprehensive analysis of Ang metabolism in biological samples, facilitating research on the physiological and pathological states of cardiovascular, kidney and respiratory diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renin-Angiotensin SystemTandem Mass SpectrometryHumansMiceAnimalsChromatography, LiquidPeptidesKidneyChromatography, High Pressure Liquid

Substanzen

Peptides

Autor:innen und Institutionen

  • MOE Key Laboratory of Standardization of Chinese Medicines and SATCM Key Laboratory of New Resources and Quality Evaluation of Chinese Medicines, Institute of Chinese Materia Medica, Shanghai University of Traditional C…
  • Shanghai R&D Center for Standardization of Chinese Medicines, Shanghai, China.

ORCID-Profile: Linnan Li

Förderung

  • National Natural Science Foundation of China
  • Program of Shanghai Municipal Health Commission

Zitieren

APA

Liu, Y., Li, L., Wang, Z., & Yang, L. (2023). A comprehensive profiling of renin–angiotensin system in mouse and human plasma by a rapid quantitative analysis of 14 angiotensin peptides using ultrahigh‐performance liquid chromatography with tandem mass spectrometry. Rapid Communications in Mass Spectrometry. https://doi.org/10.1002/rcm.9637

Vancouver

Liu Y, Li L, Wang Z, Yang L. A comprehensive profiling of renin–angiotensin system in mouse and human plasma by a rapid quantitative analysis of 14 angiotensin peptides using ultrahigh‐performance liquid chromatography with tandem mass spectrometry. Rapid Communications in Mass Spectrometry. 2023. doi:10.1002/rcm.9637

BibTeX
@article{Liu2023,
  author = {Liu, Yamin and Li, Linnan and Wang, Zhengtao and Yang, Li},
  title = {A comprehensive profiling of renin–angiotensin system in mouse and human plasma by a rapid quantitative analysis of 14 angiotensin peptides using ultrahigh‐performance liquid chromatography with tandem mass spectrometry},
  journal = {Rapid Communications in Mass Spectrometry},
  year = {2023},
  doi = {10.1002/rcm.9637}
}
Kostenlos starten →