A simple method for rapid removal of the memory effect in cavity ring‐down spectroscopy water isotope measurements
Rapid Communications in Mass Spectrometry · 15.10.2023 · 37 (19)
DOI: 10.1002/rcm.9600 ↗Kurz gefasst
Fachartikel in der Zeitschrift Rapid Communications in Mass Spectrometry, online erschienen am 08.08.2023. Verfasst von Jonathan Keinan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Earth Sciences, The Hebrew University of Jerusalem, Jerusalem, Israel. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Israel Science Foundation, Climate Crisis Scholarship of the Jewish National Fund.
Abstract (Originalsprache)
Rationale
The accuracy determined in the routine analysis of water isotopes (δ 17 O, δ 18 O, δ 2 H) using cavity ring‐down spectroscopy is greatly affected by the memory effect (ME), a sample‐to‐sample carryover that biases measurements. This study aims to develop a simple method that rapidly removes the ME.
Methods
We developed a method, designed for the Picarro L2140‐i, that removes the ME by injecting small amounts of water with an extreme isotopic value (“kick”) in the opposite direction of the ME. We conducted 11 experiments to identify the optimal kick for pairs of isotopically enriched and depleted samples. Once quantified, the optimal kick was used to create an ME‐free, unbiased calibration curve, which was verified using international and internal lab standards.
Results
Our kick method removes the ME very efficiently in half the time it takes for experiments without a kick. The optimal number of kick injections required to minimize stabilization time between standards of different compositions is three injections of δ 2 H ≈ −1000‰ water per a 100‰ difference between standards. Three runs of routine measurements using the kick method resulted in uncertainties of 0.03‰, 0.2‰, and 5 permeg for δ 18 O, δ 2 H, and 17 O‐excess, respectively.
Conclusions
This study demonstrates a new method for rapidly removing the ME. Our kick protocol is a readily available, cheap, and efficient approach to reduce instrumental bias and improve measurement accuracy.
Autor:innen und Institutionen
- Institute of Earth Sciences, The Hebrew University of Jerusalem, Jerusalem, Israel.
- Geological Survey of Israel, Jerusalem, Israel.
ORCID-Profile: Jonathan Keinan, Yonaton Goldsmith
Förderung
- Israel Science Foundation
- Climate Crisis Scholarship of the Jewish National Fund
Zitieren
APA
Keinan, J., & Goldsmith, Y. (2023). A simple method for rapid removal of the memory effect in cavity ring‐down spectroscopy water isotope measurements. Rapid Communications in Mass Spectrometry, 37(19). https://doi.org/10.1002/rcm.9600
Vancouver
Keinan J, Goldsmith Y. A simple method for rapid removal of the memory effect in cavity ring‐down spectroscopy water isotope measurements. Rapid Communications in Mass Spectrometry. 2023;37(19). doi:10.1002/rcm.9600
BibTeX
@article{Keinan2023,
author = {Keinan, Jonathan and Goldsmith, Yonaton},
title = {A simple method for rapid removal of the memory effect in cavity ring‐down spectroscopy water isotope measurements},
journal = {Rapid Communications in Mass Spectrometry},
year = {2023},
volume = {37},
number = {19},
doi = {10.1002/rcm.9600}
}
EUVIMED