Two common pitfalls in the analysis of water‐stable isotopologues with cryogenic vacuum extraction and cavity ring‐down spectroscopy
Analytical Science Advances · 2024-04 · 5 (3-4)
DOI: 10.1002/ansa.202300053 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Science Advances, online erschienen am 25.01.2024. Verfasst von Simon Haberstroh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ecosystem Physiology Faculty of Environment and Natural Resources Institute of Earth and Environmental Sciences University Freiburg Freiburg Germany. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Water stable isotopologue analysis is widely used to disentangle ecohydrological processes. Yet, there are increasing reports of measurement uncertainties for established and emerging methods, such as cryogenic vacuum extraction (CVE) or cavity ring‐down spectroscopy (CRDS). With this study, we investigate two pitfalls, that potentially contribute to uncertainties in water‐stable isotopologue research. To investigate fractionation sources in CVE, we extracted pure water of known isotopic composition with cotton, glass wool or without cover and compared the isotopologue results with non‐extracted reference samples. To characterise the dependency of δ 2 H and δ 18 O on the water mixing ratio in CRDS, which is of high importance for in‐situ applications with large natural variations in mixing ratios, we chose samples with a large range of isotopic compositions and determined δ 2 H and δ 18 O for different water mixing ratios with two CRDS analysers (Picarro, Inc.). Cotton wool had a strong fractionation effect on δ 2 H values, which increased with more 2 H‐enriched samples. δ 2 H and δ 18 O values showed a strong dependency on the water mixing ratio analysed with CRDS with differences of up to 34.5‰ (δ 2 H) and 3.9‰ (δ 18 O) for the same sample at different mixing ratios. CVE and CRDS, now routinely applied in water stable isotopologue research, come with pitfalls, namely fractionation effects of cover materials and water mixing ratio dependencies of δ 2 H and δ 18 O, which can lead to erroneous isotopologue results and thus, invalid conclusions about (ecohydrological) processes. These practical issues identified here should be reported and addressed adequately in water‐stable isotopologue research.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ecosystem Physiology Faculty of Environment and Natural Resources Institute of Earth and Environmental Sciences University Freiburg Freiburg Germany.
- Institute for Atmospheric and Earth System Research (INAR) University of Helsinki Helsinki Finland.
ORCID-Profile: Simon Haberstroh, Angelika Kübert, Christiane Werner
Förderung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Haberstroh, S., Kübert, A., & Werner, C. (2024). Two common pitfalls in the analysis of water‐stable isotopologues with cryogenic vacuum extraction and cavity ring‐down spectroscopy. Analytical Science Advances, 5(3-4). https://doi.org/10.1002/ansa.202300053
Vancouver
Haberstroh S, Kübert A, Werner C. Two common pitfalls in the analysis of water‐stable isotopologues with cryogenic vacuum extraction and cavity ring‐down spectroscopy. Analytical Science Advances. 2024;5(3-4). doi:10.1002/ansa.202300053
BibTeX
@article{Haberstroh2024,
author = {Haberstroh, Simon and Kübert, Angelika and Werner, Christiane},
title = {Two common pitfalls in the analysis of water‐stable isotopologues with cryogenic vacuum extraction and cavity ring‐down spectroscopy},
journal = {Analytical Science Advances},
year = {2024},
volume = {5},
number = {3-4},
doi = {10.1002/ansa.202300053}
}
EUVIMED