Cystoscopic ICG‐Guided Sentinel Lymph Node Dissection in Robotic Radical Prostatectomy: A Prospective Study
The Prostate · 2026
DOI: 10.1002/pros.70107 ↗At a glance
Journal article in The Prostate, 2026. Written by Yi Hong Li and 7 co-authors. Institution: Division of Urology, Department of Surgery, Tungs' Taichung MetroHarbor Hospital, Taichung City, Taiwan. Major MEDLINE topics: Prostatectomy, Prostatic Neoplasms, Robotic Surgical Procedures, Indocyanine Green. Cited 2 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY-NC 4.0).
Abstract (original language)
Background
To evaluate the diagnostic accuracy, procedural feasibility, and clinical outcomes of a novel cystoscopic‐guided indocyanine green (ICG) injection technique followed by fluorescence‐guided sentinel lymph node dissection (SLND) during robotic‐assisted radical prostatectomy (RaRP), hereafter referred to as CysICG‐SLND .
Methods
We prospectively enrolled patients with clinically localized prostate cancer (cT1–cT3, cN0) scheduled for RaRP between November 2019 and May 2020. Each patient received cystoscopic‐guided intraprostatic injections of ICG, with injection volumes tailored according to prostate size. SLND was performed using the da Vinci Xi Surgical System equipped with near‐infrared imaging and followed by a routine extended pelvic lymph node dissection (ePLND). Diagnostic accuracy, procedural complications, and medium‐term oncological outcomes were analyzed.
Results
A total of 34 patients were included (risk category: low = 2, intermediate = 11, high = 21). Cystoscopic ICG injection was technically successful in all cases. The overall fluorescence detection rate was 97.1%, with excellent per‐patient sensitivity (100%) and negative predictive value (NPV) (100%) across all patients. However, per‐node diagnostic performance was moderate (sensitivity 66.7%, specificity 47.8%). Notably, in the high‐risk group, per‐node performance was modest, with sensitivity, specificity, positive predictive value (PPV), and NPV of 66.7%, 55.2%, 20.5%, and 90.7%, respectively. No metastatic nodes were identified in low‐risk and intermediate‐risk groups, demonstrating a reliable 100% NPV in these subpopulations. High‐risk patients had significantly higher biochemical recurrence (BCR) rates compared to lower‐risk groups ( p = 0.017). There were no allergic reactions or postoperative complications attributable to ICG.
Conclusions
CysICG‐SLND is a feasible, accurate approach for nodal staging in prostate cancer, particularly beneficial in low‐ to intermediate‐risk groups, achieving excellent sensitivity and NPV. Although diagnostic performance is limited in high‐risk patients, high per‐patient accuracy still supports clinical utility. Larger prospective studies are warranted to validate these results and further elucidate the technique's clinical role.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Division of Urology, Department of Surgery, Tungs' Taichung MetroHarbor Hospital, Taichung City, Taiwan.
ORCID profiles: Yi Hong Li
Cite
APA
Li, Y. H., Chuang, Y. F., Ou, Y. C., Lin, Y. S., Huang, L. H., Weng, W. C., Hsu, C. Y., & Tung, M. C. (2026). Cystoscopic ICG‐Guided Sentinel Lymph Node Dissection in Robotic Radical Prostatectomy: A Prospective Study. The Prostate. https://doi.org/10.1002/pros.70107
Vancouver
Li YH, Chuang YF, Ou YC, Lin YS, Huang LH, Weng WC, et al. Cystoscopic ICG‐Guided Sentinel Lymph Node Dissection in Robotic Radical Prostatectomy: A Prospective Study. The Prostate. 2026. doi:10.1002/pros.70107
BibTeX
@article{Li2026,
author = {Li, Yi Hong and Chuang, Yu Feng and Ou, Yen Chuan and Lin, Yi Sheng and Huang, Li Hua and Weng, Wei Chun and Hsu, Chao Yu and Tung, Min Che},
title = {Cystoscopic ICG‐Guided Sentinel Lymph Node Dissection in Robotic Radical Prostatectomy: A Prospective Study},
journal = {The Prostate},
year = {2026},
doi = {10.1002/pros.70107}
}
EUVIMED