A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins
Protein Science · 2025-08 · 34 (8)
DOI: 10.1002/pro.70214 ↗At a glance
Journal article in Protein Science, published online on 2025-07-16. Written by Alexander M Garces and 4 co-authors. Institution: Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, USA. Major MEDLINE topics: Spin Labels, Muramidase, Receptors, Adrenergic, beta-2. Cited 4 times so far (Crossref); 91 references. The full text is freely available in PubMed Central. Funded by: NIGMS NIH HHS, National Institute of General Medical Sciences.
Abstract (original language)
Electron paramagnetic resonance (EPR) spectroscopy is a powerful tool for studying biological systems, with applications in drug discovery, protein dynamics, membrane biology, and enzyme mechanisms. However, sample volume requirements and sensitivity limitations have historically constrained time‐resolved measurements of protein dynamics using stopped‐flow (SF) EPR spectroscopy. To address these challenges, we developed a high‐sensitivity SF EPR system featuring a custom dielectric resonator, an optimized low‐volume sample tube geometry design, and the SF mixer assembly integrated into the resonator housing. This system significantly reduces sample requirements for the investigation of protein conformational dynamics on the millisecond timescale. We demonstrate its capabilities through two applications: the analysis of T4 lysozyme unfolding kinetics, which revealed site‐specific variations in the folding pathway, and the measurement of ligand‐induced conformational changes in the β2 adrenergic receptor, a challenging membrane‐protein system. This advancement broadens the applicability of SF EPR to complex, biomedically relevant proteins, facilitating studies of protein–protein and protein–ligand interactions in diverse biological processes.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Biophysics, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
- Department of Physics and Chemistry, Milwaukee School of Engineering, Milwaukee, Wisconsin, USA.
ORCID profiles: Alexander M Garces, Candice S Klug, Jason W Sidabras, Michael T Lerch
Funding
- NIGMS NIH HHS
- National Institute of General Medical Sciences
Cite
APA
Garces, A. M., Mett, R. R., Klug, C. S., Sidabras, J. W., & Lerch, M. T. (2025). A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins. Protein Science, 34(8). https://doi.org/10.1002/pro.70214
Vancouver
Garces AM, Mett RR, Klug CS, Sidabras JW, Lerch MT. A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins. Protein Science. 2025;34(8). doi:10.1002/pro.70214
BibTeX
@article{Garces2025,
author = {Garces, Alexander M and Mett, Richard R and Klug, Candice S and Sidabras, Jason W and Lerch, Michael T},
title = {A high‐sensitivity stopped‐flow EPR system to monitor millisecond conformational kinetics in spin‐labeled proteins},
journal = {Protein Science},
year = {2025},
volume = {34},
number = {8},
doi = {10.1002/pro.70214}
}
EUVIMED