An intein‐based biosensor to measure protein stability in vivo
Protein Science · 2024
DOI: 10.1002/pro.4925 ↗At a glance
Journal article in Protein Science, 2024. Written by Ahyun Son and 3 co-authors. Institution: Department of Chemistry & Biochemistry, Knoebel Institute for Healthy Aging, University of Denver, Denver, Colorado, USA. Major MEDLINE topics: Inteins, Protein Splicing. Cited 3 times so far (Crossref); 22 references. The full text is freely available in PubMed Central. Funded by: NIGMS NIH HHS, NIH HHS, National Institutes of Health.
Abstract (original language)
Biosensors to measure protein stability in vivo are valuable tools for a variety of applications. Previous work has demonstrated that a tripartite design, whereby a protein of interest (POI) is inserted within a reporter, can link POI stability to reporter activity. Inteins are translated within other proteins and excised in a self‐mediated protein splicing reaction. Here, we developed a novel folding biosensor where a POI is inserted within an intein, which is subsequently translated within an antibiotic resistance marker. We showed that protein splicing is required for antibiotic resistance and that housing a stable POI within the intein, compared to an unstable variant, results in a 100,000‐fold difference in survival. Further, using a fluorescent protein that matures slowly as the POI, we developed a reporter with two simultaneous readouts for protein folding. Finally, we showed that co‐expression of GroEL can significantly increase the activity of both reporters, further verifying that protein folding factors can act on the POI in the biosensor. As a whole, our work provides a new twist on the traditional tripartite approach to measuring protein stability in vivo.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Chemistry & Biochemistry, Knoebel Institute for Healthy Aging, University of Denver, Denver, Colorado, USA.
- Department of Biological Sciences, Murray State University, Murray, Kentucky, USA.
ORCID profiles: Ahyun Son, Scott Horowitz, Christopher W Lennon
Funding
- NIGMS NIH HHS
- NIH HHS
- National Institutes of Health
Cite
APA
Son, A., Smetana, J. S., Horowitz, S., & Lennon, C. W. (2024). An intein‐based biosensor to measure protein stability in vivo. Protein Science. https://doi.org/10.1002/pro.4925
Vancouver
Son A, Smetana JS, Horowitz S, Lennon CW. An intein‐based biosensor to measure protein stability in vivo. Protein Science. 2024. doi:10.1002/pro.4925
BibTeX
@article{Son2024,
author = {Son, Ahyun and Smetana, John S and Horowitz, Scott and Lennon, Christopher W},
title = {An intein‐based biosensor to measure protein stability in vivo},
journal = {Protein Science},
year = {2024},
doi = {10.1002/pro.4925}
}
EUVIMED