EUVIMEDEUVIMED entdecken
Open Access

An intein‐based biosensor to measure protein stability in vivo

Ahyun Son iD, John S Smetana, Scott Horowitz iD, Christopher W Lennon iD

Protein Science · 2024

DOI: 10.1002/pro.4925 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Protein Science, 2024. Verfasst von Ahyun Son und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry & Biochemistry, Knoebel Institute for Healthy Aging, University of Denver, Denver, Colorado, USA. Hauptthemen laut MEDLINE: Inteins, Protein Splicing. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biosensors to measure protein stability in vivo are valuable tools for a variety of applications. Previous work has demonstrated that a tripartite design, whereby a protein of interest (POI) is inserted within a reporter, can link POI stability to reporter activity. Inteins are translated within other proteins and excised in a self‐mediated protein splicing reaction. Here, we developed a novel folding biosensor where a POI is inserted within an intein, which is subsequently translated within an antibiotic resistance marker. We showed that protein splicing is required for antibiotic resistance and that housing a stable POI within the intein, compared to an unstable variant, results in a 100,000‐fold difference in survival. Further, using a fluorescent protein that matures slowly as the POI, we developed a reporter with two simultaneous readouts for protein folding. Finally, we showed that co‐expression of GroEL can significantly increase the activity of both reporters, further verifying that protein folding factors can act on the POI in the biosensor. As a whole, our work provides a new twist on the traditional tripartite approach to measuring protein stability in vivo.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

InteinsProtein SplicingProteins

Stichwörter der Autor:innen

biosensorchaperoneinteinprotein foldingprotein splicing

Substanzen

Proteins

Autor:innen und Institutionen

  • Department of Chemistry & Biochemistry, Knoebel Institute for Healthy Aging, University of Denver, Denver, Colorado, USA.
  • Department of Biological Sciences, Murray State University, Murray, Kentucky, USA.

ORCID-Profile: Ahyun Son, Scott Horowitz, Christopher W Lennon

Förderung

  • NIGMS NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Son, A., Smetana, J. S., Horowitz, S., & Lennon, C. W. (2024). An intein‐based biosensor to measure protein stability in vivo. Protein Science. https://doi.org/10.1002/pro.4925

Vancouver

Son A, Smetana JS, Horowitz S, Lennon CW. An intein‐based biosensor to measure protein stability in vivo. Protein Science. 2024. doi:10.1002/pro.4925

BibTeX
@article{Son2024,
  author = {Son, Ahyun and Smetana, John S and Horowitz, Scott and Lennon, Christopher W},
  title = {An intein‐based biosensor to measure protein stability in vivo},
  journal = {Protein Science},
  year = {2024},
  doi = {10.1002/pro.4925}
}
Kostenlos starten →