Fachartikel in der Zeitschrift Physiotherapy Research International, online erschienen am 21.07.2026. Verfasst von Heverson Felipe Pranches Carneiro und 3 weiteren Autor:innen. Beteiligte Einrichtung: Universidade Nove de Julho, São Paulo, Brazil. Hauptthemen laut MEDLINE: Renal Dialysis, Kidney Failure, Chronic, Exercise Test, Walk Test. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Finance Code 001, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Background
Functional impairments are common in individuals with end‐stage renal disease (ESRD) undergoing hemodialysis (HD); however, the clinical assessment of physical function remains challenging due to the limited availability of simple and reliable functional tests validated for this population.
Purpose
To evaluate the test‐retest reproducibility of the 6‐minute step test (6MST) in individuals undergoing HD, including the interpretation of measurement error.
Methods
This was a cross‐sectional, test retest‐ reliability study conducted in patients receiving maintenance HD. All assessments were performed immediately before the HD session. Participants completed the Kidney Disease Quality of Life 36‐Item Short Form questionnaire (KDQOL SF‐36) and performed two 6MSTs under standardized conditions. Test‐retest reliability was assessed using the intraclass correlation coefficient (ICC). Absolute reliability was evaluated through the standard error of measurement (SEM) and minimal detectable change (MDC). Agreement between tests was examined using Bland–Altman analysis.
Results
Fifty patients completed both test sessions. The 6MST demonstrated good test–retest reliability for total steps (ICC = 0.80), with most differences between tests remaining below the MDC95, indicating the absence of a clinically meaningful learning effect. Bland–Altman analysis showed minimal bias and acceptable limits of agreement for both total steps and heart rate measured at the sixth minute of the test. Physiological responses, including oxygen saturation, blood pressure, and perceived exertion, remained stable between sessions.
Discussion
The 6 minute step test is a reliable and clinically applicable tool for assessing functional capacity in individuals undergoing hemodialysis. The absence of a relevant learning effect and the stability of physiological responses support its use for functional assessment and follow‐up, even when performed before the hemodialysis session. Further studies should investigate inter‐rater reproducibility and responsiveness to interventions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Universidade Nove de Julho, São Paulo, Brazil.
ORCID-Profile: Heverson Felipe Pranches Carneiro, Thamiê Cristina Stella, Ivan Peres Costa, Luciana Maria Malosá Sampaio
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior-Finance Code 001
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Carneiro, H. F. P., Stella, T. C., Costa, I. P., & Sampaio, L. M. M. (2026). Reproducibility of the 6‐Minute Step Test in Individuals on Hemodialysis. Physiotherapy Research International, 31(3). https://doi.org/10.1002/pri.70291
Vancouver
Carneiro HFP, Stella TC, Costa IP, Sampaio LMM. Reproducibility of the 6‐Minute Step Test in Individuals on Hemodialysis. Physiotherapy Research International. 2026;31(3). doi:10.1002/pri.70291
BibTeX
@article{Carneiro2026,
author = {Carneiro, Heverson Felipe Pranches and Stella, Thamiê Cristina and Costa, Ivan Peres and Sampaio, Luciana Maria Malosá},
title = {Reproducibility of the 6‐Minute Step Test in Individuals on Hemodialysis},
journal = {Physiotherapy Research International},
year = {2026},
volume = {31},
number = {3},
doi = {10.1002/pri.70291}
}
EUVIMED