EUVIMEDObjevte EUVIMED
Crossref

The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals

Merve Keskin iD, Erhan Secer, Derya Ozer Kaya

Physiotherapy Research International · 2026-04 · 31 (2)

DOI: 10.1002/pri.70171 ↗

At a glance

Journal article in Physiotherapy Research International, published online on 2026-02-11. Written by Merve Keskin and 2 co-authors. Institution: Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, İzmir Katip Celebi University, İzmir, Türkiye. Major MEDLINE topics: Reaction Time, Upper Extremity, Psychomotor Performance, Motor Skills. 24 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background and Purpose To determine the test‐retest reliability and minimal detectable change of the Brain Pro System (Brain Pro System, Poland) for assessing upper extremity visuo‐motor reaction time (V‐MRT) in physically active healthy individuals.

Methods

Sixty‐four physically active healthy participants (M age = 21.26, SD = 0.94 years) completed two assessments 1 week apart. Reliability was assessed using ICC2,1 with a 95% confidence interval. The standard error of measurement and MDC95 were calculated. Stability was analyzed with Cronbach's α and coefficient of variation (CV).

Results

The Brain Pro System demonstrated excellent reliability for right, left, and randomly determined upper extremity V‐MRT (ICC2,1 = 0.95–0.97, α = 0.95–0.97, CV = 0.01). The MDC values were 1.21 s for right and left V‐MRT and 1.10 s for combined extremities.

Discussion

The Brain Pro System is highly reliable for assessing V‐MRT. The MDC values provide a reference for evaluating meaningful changes in reaction time for physically active, healthy adults.

Subjects

MeSH terms (MEDLINE)

Reaction TimeUpper ExtremityPsychomotor PerformanceMotor SkillsHumansMaleReproducibility of ResultsFemaleYoung AdultAdult

Author keywords

motor skillsphysical fitnessresponse timetask performance

Authors and institutions

  • Department of Physiotherapy and Rehabilitation, Faculty of Health Sciences, İzmir Katip Celebi University, İzmir, Türkiye.
  • Physiotherapy and Rehabilitation Application and Research Center, İzmir Katip Celebi University, İzmir, Türkiye.
  • Department of Health Care Services, Vocational School of Health Services, Manisa Celal Bayar University, Manisa, Türkiye.

ORCID profiles: Merve Keskin

Cite

APA

Keskin, M., Secer, E., & Kaya, D. O. (2026). The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals. Physiotherapy Research International, 31(2). https://doi.org/10.1002/pri.70171

Vancouver

Keskin M, Secer E, Kaya DO. The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals. Physiotherapy Research International. 2026;31(2). doi:10.1002/pri.70171

BibTeX
@article{Keskin2026,
  author = {Keskin, Merve and Secer, Erhan and Kaya, Derya Ozer},
  title = {The Test‐Retest Reliability and Minimal Detectable Change of the Brain Pro System for Assessing Upper Extremity Visuo‐Motor Reaction Time in Physically Active Healthy Individuals},
  journal = {Physiotherapy Research International},
  year = {2026},
  volume = {31},
  number = {2},
  doi = {10.1002/pri.70171}
}
Start for free →