The Minimal Clinically Important Difference of the 180° Turn Time During the Instrumented Timed up and Go in Unilateral Vestibulopathies
Physiotherapy Research International · 2025
DOI: 10.1002/pri.70053 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Physiotherapy Research International, 2025. Verfasst von Ann Hallemans und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Sciences and Physiotherapy/Movant, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium. Hauptthemen laut MEDLINE: Gait, Minimal Clinically Important Difference, Postural Balance, Vestibular Diseases. Die Arbeit nennt 19 Literaturangaben. Gefördert von: Universiteit Antwerpen.
Abstract (Originalsprache)
Background and Purpose The Timed Up and Go test (TUG) assesses dynamic balance performance. Motion sensors such as gyroscopes have enabled evaluation of the various subtasks of the TUG such as the 180° turn. As fast turning triggers the vestibular system, we hypothesize that the 180° turn is sensitive to change in individuals with unilateral vestibulopathies (UVP). Therefore, the objectives of this study were to formulate the minimal detectable change and minimal clinically important difference (MCID), both anchor‐ and distribution‐based, for the 180° turn time in individuals with UVP.
Methods
In this longitudinal prospective study, data were collected in secondary and tertiary hospitals. Participants were included up to 4 weeks after the onset of the UVP. Unilateral vestibular function loss was confirmed by the criteria of the Bárány society. At baseline and follow‐up (10 weeks since onset), participants performed an instrumented version of the TUG and a tandem gait test. An anchor‐ and distribution‐based MCID was calculated for the 180° turn time.
Results
Seventy participants (55 ± 17 years, 35 female) were included. A minimal detectable change of 0.69 s (180° turn time) was calculated. The anchor‐, and distribution‐based MCID were 0.71 and 0.63 s for the 180° turn time, respectively.
Discussion
In individuals with UVP, an MCID of 0.71 s was observed for the 180° turn time. More research is recommended to confirm our results. Trial Registration: clinicaltrials.gov under ID NCT04979598
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation Sciences and Physiotherapy/Movant, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
- Multidisciplinary Motor Centre Antwerp (M²OCEAN), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
- Department of Physiotherapy, Bern University of Applied Sciences, Bern, Switzerland.
- Department of Otorhinolaryngology and Head and Neck Surgery, Antwerp University Hospital, Antwerp, Belgium.
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
ORCID-Profile: Lien Van Laer
Förderung
- Universiteit Antwerpen
Zitieren
APA
Hallemans, A., Van der Boon, H., Vereeck, L., Van Rompaey, V., & Van Laer, L. (2025). The Minimal Clinically Important Difference of the 180° Turn Time During the Instrumented Timed up and Go in Unilateral Vestibulopathies. Physiotherapy Research International. https://doi.org/10.1002/pri.70053
Vancouver
Hallemans A, Van der Boon H, Vereeck L, Van Rompaey V, Van Laer L. The Minimal Clinically Important Difference of the 180° Turn Time During the Instrumented Timed up and Go in Unilateral Vestibulopathies. Physiotherapy Research International. 2025. doi:10.1002/pri.70053
BibTeX
@article{Hallemans2025,
author = {Hallemans, Ann and Van der Boon, Hendrik and Vereeck, Luc and Van Rompaey, Vincent and Van Laer, Lien},
title = {The Minimal Clinically Important Difference of the 180° Turn Time During the Instrumented Timed up and Go in Unilateral Vestibulopathies},
journal = {Physiotherapy Research International},
year = {2025},
doi = {10.1002/pri.70053}
}
EUVIMED