EUVIMEDDescubrir EUVIMED
Crossref

Intrarater and interrater reliability of digital calipers in assessing Achilles tendon thickness in patients with knee osteoarthritis

Shaikh Nabi Bukhsh Nazir iD, Basit Ansari

Physiotherapy Research International · 2024

DOI: 10.1002/pri.2107 ↗

At a glance

Journal article in Physiotherapy Research International, 2024. Written by Shaikh Nabi Bukhsh Nazir and 1 co-authors. Institution: Department of Health, Physical Education, and Sports Sciences, University of Karachi, Karachi, Pakistan. Major MEDLINE topics: Osteoarthritis, Knee, Achilles Tendon, Observer Variation. Cited 2 times so far (Crossref); 23 references.

ResumenSubjectsDatos bibliográficosCiteRelated studies

Abstract (original language)

Objective

This study aimed to evaluate the intrarater and interrater reliability of measuring Achilles tendon (AT) thickness using a digital caliper in patients with knee osteoarthritis.

Methods

A cross‐sectional survey was conducted at the Physiotherapy Department of Rabia Moon Hospital, involving the recruitment of 61 patients with knee osteoarthritis. Measurements were taken in millimeters at a 90‐degree angle, approximately 5 cm from the attachment to the calcaneus, precisely where the ankle joint joins the medial malleolus. Two physical therapists conducted two testing sessions, separated by 7 days, to assess both the intrarater and interrater reliability of the digital caliper. During the second session, two raters simultaneously assessed the patients' responses on the digital caliper. The study analyzed reliability indices, including the Intraclass Correlation Coefficient (ICC) and Bland–Altman plot.

Results

The study found high intrarater reliability for the digital caliper, with an ICC of 0.96 (95% confidence interval: 0.22, 0.99). For interrater reliability, the ICC was 0.98 (95% CI: 0.96, 0.98) in patients with knee OA. Additionally, both interrater and intrarater agreement for measuring AT thickness with the digital caliper fell within acceptable limits on 95% of occasions, as indicated by the Limits of Agreement values: 0.32 to −0.53 mm for interrater agreement and −0.35 to −0.04 mm for intrarater agreement.

Conclusions

Digital Calipers have been found to provide excellent intrarater and interrater reliability when used to measure AT thickness in patients with knee osteoarthritis (OA).

Subjects

MeSH terms (MEDLINE)

Osteoarthritis, KneeAchilles TendonObserver VariationHumansMaleFemaleCross-Sectional StudiesReproducibility of ResultsMiddle AgedAged

Author keywords

Achilles tendon ruptureknee jointosteoarthritistendon elongation

Authors and institutions

  • Department of Health, Physical Education, and Sports Sciences, University of Karachi, Karachi, Pakistan.

ORCID profiles: Shaikh Nabi Bukhsh Nazir

Cite

APA

Nazir, S. N. B., & Ansari, B. (2024). Intrarater and interrater reliability of digital calipers in assessing Achilles tendon thickness in patients with knee osteoarthritis. Physiotherapy Research International. https://doi.org/10.1002/pri.2107

Vancouver

Nazir SNB, Ansari B. Intrarater and interrater reliability of digital calipers in assessing Achilles tendon thickness in patients with knee osteoarthritis. Physiotherapy Research International. 2024. doi:10.1002/pri.2107

BibTeX
@article{Nazir2024,
  author = {Nazir, Shaikh Nabi Bukhsh and Ansari, Basit},
  title = {Intrarater and interrater reliability of digital calipers in assessing Achilles tendon thickness in patients with knee osteoarthritis},
  journal = {Physiotherapy Research International},
  year = {2024},
  doi = {10.1002/pri.2107}
}
Start for free →