Continuous Application of Closed‐Loop FiO2‐Control in Extremely Preterm Infants: A Matched Cohort Single‐Center Study

Koen P Dijkman iD, Jesse J Delbressine, Jeanne P Dieleman, Thilo Mohns, Peter Andriessen, Carola van Pul, Irwin K M Reiss, Axel R Franz, Hendrik J Niemarkt iD

Pediatric Pulmonology · 2025

DOI: 10.1002/ppul.71122 ↗

At a glance

Journal article in Pediatric Pulmonology, 2025. Written by Koen P Dijkman and 8 co-authors. Institution: Department of Neonatology, Máxima MC, Veldhoven, The Netherlands. Major MEDLINE topics: Infant, Extremely Premature, Oxygen Inhalation Therapy, Oxygen Saturation, Oxygen. Cited 5 times so far (Crossref); 22 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: The authors received no specific funding for this work..

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Automated or closed‐loop FiO2‐control (FiO2‐c) has been developed to maintain oxygen saturation (SpO2) within a target range more effectively. However, knowledge of the effects of prolonged use of FiO2‐c in extremely preterm infants during a more integral part of NICU admission is limited.

Methods

Twenty five extremely preterm infants (gestational age [GA] < 28 weeks) who survived until NICU discharge andreceived FiO2‐c by Predictive Intelligent Control of Oxygenation (PRICO) were matched 1:1 for GA, birthweight, sex andsurvival to a cohort receiving routine manual FiO2 control. The proportions of time within the SpO2 target range, (severe) hypoxia, hyperoxia, FiO2 and SpO2 for all days and days on supplemental oxygen, for both the whole period and per week, were compared.

Results

Infants in the FiO2‐c cohort received the intervention during 98% of the 7‐week study period. Overall, with FiO2‐c, a small, non‐significant increase in time within SpO2 target range was observed: mean difference 0.5% (95% CI [−5.0, 6.0]). However, when requiring supplemental oxygen during the first 2 weeks of life, time within SpO2 target range significantly increased with FiO2‐c, while time in hyperoxia decreased: mean differences in Week 1: 9.9% (95% CI [3.1, 16.7]) and −10.2% (95% CI [−17.1, −3.3]); in Week 2: 9.5% (95% CI [1.4, 17.6]) and −9.9% (95% CI [−19.2, −0.2]).

Conclusion

Despite limited overall effect, continuous use of FiO2‐c in extremely preterm infants requiring supplemental oxygen was associated with an increased time within the SpO2 target range during the first 2 weeks of life, a critical window for hyperoxia‐related diseases.

Subjects

MeSH terms (MEDLINE)

Infant, Extremely PrematureOxygen Inhalation TherapyOxygen SaturationOxygenHumansInfant, NewbornMaleFemaleHyperoxiaCohort StudiesIntensive Care Units, NeonatalHypoxiaGestational AgeOximetry

Author keywords

automated oxygen controlclosed loop oxygen controlhyperoxiahypoxiapreterm

Substances

Oxygen

Authors and institutions

  • Department of Neonatology, Máxima MC, Veldhoven, The Netherlands.
  • Department of Applied Physics, TU/e Eindhoven, University of Technology, Eindhoven, The Netherlands.
  • MMC Science Office, Máxima MC, Veldhoven, The Netherlands.
  • Department of Clinical Physics, Máxima MC, Veldhoven, The Netherlands.
  • Department of Neonatal and Pediatric Intensive Care, Division of Neonatology, Erasmus MC, Rotterdam, The Netherlands.
  • Department of Neonatology and Centre for Paediatric Clinical Studies, University Children's Hospital Tübingen, Tübingen, Baden-Württemberg, Germany.

ORCID profiles: Koen P Dijkman, Hendrik J Niemarkt

Funding

  • The authors received no specific funding for this work.

Cite

APA

Dijkman, K. P., Delbressine, J. J., Dieleman, J. P., Mohns, T., Andriessen, P., Pul, C. V., Reiss, I. K. M., Franz, A. R., & Niemarkt, H. J. (2025). Continuous Application of Closed‐Loop FiO2‐Control in Extremely Preterm Infants: A Matched Cohort Single‐Center Study. Pediatric Pulmonology. https://doi.org/10.1002/ppul.71122

Vancouver

Dijkman KP, Delbressine JJ, Dieleman JP, Mohns T, Andriessen P, Pul CV, et al. Continuous Application of Closed‐Loop FiO2‐Control in Extremely Preterm Infants: A Matched Cohort Single‐Center Study. Pediatric Pulmonology. 2025. doi:10.1002/ppul.71122

BibTeX
@article{Dijkman2025,
  author = {Dijkman, Koen P and Delbressine, Jesse J and Dieleman, Jeanne P and Mohns, Thilo and Andriessen, Peter and Pul, Carola van and Reiss, Irwin K M and Franz, Axel R and Niemarkt, Hendrik J},
  title = {Continuous Application of Closed‐Loop FiO2‐Control in Extremely Preterm Infants: A Matched Cohort Single‐Center Study},
  journal = {Pediatric Pulmonology},
  year = {2025},
  doi = {10.1002/ppul.71122}
}