The impact of PEEP on mechanical power and driving pressure in children with pediatric acute respiratory distress syndrome
Pediatric Pulmonology · 2024-12 · 59 (12) · 3593-3600
DOI: 10.1002/ppul.27266 ↗At a glance
Journal article in Pediatric Pulmonology, published online on 2024-09-12. Written by Isabel de Siqueira Ferraz and 8 co-authors. Institution: Department of Pediatrics, Pediatric Intensive Care Unit, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, São Paulo, Brazil. Major MEDLINE topics: Positive-Pressure Respiration, Respiratory Distress Syndrome. Cited 8 times so far (Crossref); 34 references. Funded by: None.
Topics: Kinderkrankenpflege
Abstract (original language)
Background
Positive end‐expiratory pressure (PEEP) is widely used to improve oxygenation and avoid alveolar collapse in mechanically ventilated patients with pediatric acute respiratory distress syndrome (PARDS). However, its improper use can be harmful, impacting variables associated with ventilation‐induced lung injury, such as mechanical power (MP) and driving pressure (∆P). Our main objective was to assess the impact of increasing PEEP on MP and ∆P in children with PARDS.
Interventions
Mechanically ventilated children on pressure‐controlled volume‐guaranteed mode were prospectively assessed for inclusion. PEEP was sequentially changed to 5, 12, 10, 8, and again to 5 cm H 2 O. After 10 min at each PEEP level, ventilatory data were collected and then variables of interest were determined. Respiratory system mechanics were measured using the least squares fitting method.
Results
Thirty‐one patients were included, with median age and weight of 6 months and 6.3 kg. Most subjects were admitted for acute viral bronchiolitis (45%) or community‐acquired pneumonia (32%) and were diagnosed with mild (45%) or moderate (42%) PARDS. There was a significant increase in MP and ∆P at PEEP levels of 10 and 12 cm H 2 O. When PEEP was increased from 5 to 12 cm H 2 O, there was a relative increase in MP of 60.7% (IQR 49.3–82.9) and in ΔP of 33.3% (IQR 17.8–65.8). A positive correlation was observed between MP and ΔP ( ρ = 0.59).
Conclusions
Children with mild or moderate PARDS may experience a significant increase in MP and ∆P with increased PEEP. Therefore, respiratory system mechanics and lung recruitability must be carefully evaluated during PEEP titration.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Pediatrics, Pediatric Intensive Care Unit, Clinics Hospital of the State University of Campinas (UNICAMP), Campinas, São Paulo, Brazil.
- Pediatric Intensive Care Unit, Sírio-Libanês Hospital, Sao Paulo, São Paulo, Brazil.
- Intensive Care Society of Sao Paulo, Sao Paulo, São Paulo, Brazil.
ORCID profiles: Marina Simões Oliveira, Tiago Henrique De Souza
Funding
- None
Cite
APA
Ferraz, I. S., Carioca, F. L., Junqueira, F. M. D., Oliveira, M. S., Duarte, G. L., Foronda, F. K., Matsumoto, T., Brandão, M. B., & De Souza, T. H. (2024). The impact of PEEP on mechanical power and driving pressure in children with pediatric acute respiratory distress syndrome. Pediatric Pulmonology, 59(12), 3593-3600. https://doi.org/10.1002/ppul.27266
Vancouver
Ferraz IS, Carioca FL, Junqueira FMD, Oliveira MS, Duarte GL, Foronda FK, et al. The impact of PEEP on mechanical power and driving pressure in children with pediatric acute respiratory distress syndrome. Pediatric Pulmonology. 2024;59(12):3593-3600. doi:10.1002/ppul.27266
BibTeX
@article{Ferraz2024,
author = {Ferraz, Isabel de Siqueira and Carioca, Fernando de Lima and Junqueira, Fernanda Monteiro Diniz and Oliveira, Marina Simões and Duarte, Gregory Lui and Foronda, Flávia Krepel and Matsumoto, Toshio and Brandão, Marcelo Barciela and De Souza, Tiago Henrique},
title = {The impact of PEEP on mechanical power and driving pressure in children with pediatric acute respiratory distress syndrome},
journal = {Pediatric Pulmonology},
year = {2024},
volume = {59},
number = {12},
pages = {3593--3600},
doi = {10.1002/ppul.27266}
}
EUVIMED