EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Oscillometry and spirometry are not interchangeable when assessing the bronchodilator response in children and young adults born preterm

Elizabeth F Smith, Tiffany K Bradshaw iD, Rhea C Urs, Denby J Evans iD, Naomi R Hemy, Graham L Hall, Andrew C Wilson, Shannon J Simpson

Pediatric Pulmonology · 2023-11 · 58 (11) · 3122-3132

DOI: 10.1002/ppul.26632 ↗

At a glance

Journal article in Pediatric Pulmonology, published online on 2023-08-04. Written by Elizabeth F Smith and 7 co-authors. Institution: Wal-Yan Respiratory Research Centre, Telethon Kids Institute, Perth Children's Hospital, Nedlands, Australia. Major MEDLINE topics: Bronchodilator Agents, Albuterol. Cited 7 times so far (Crossref); 48 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Health and Medical Research Council.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

The European Respiratory Society Oscillometry Taskforce identified that clinical correlates of bronchodilator responses are needed to advance oscillometry in clinical practice. The understanding of bronchodilator‐induced oscillometry changes in preterm lung disease is poor. Here we describe a comparison of bronchodilator assessments performed using oscillometry and spirometry in a population born very preterm and explore the relationship between bronchodilator‐induced changes in respiratory function and clinical outcomes.

Methods

Participants aged 6–23 born ≤32 ( N = 288; 132 with bronchopulmonary dysplasia) and ≥37 weeks' gestation ( N = 76, term‐born controls) performed spirometry and oscillometry. A significant bronchodilator response (BDR) to 400 μg salbutamol was classified according to published criteria.

Results

A BDR was identified in 30.9% ( n = 85) of preterm‐born individuals via spirometry and/or oscillometry, with poor agreement between spirometry and oscillometry definitions ( k = 0.26; 95% confidence interval [CI] 0.18–0.40, p < .001). Those born preterm with a BDR by oscillometry but not spirometry had increased wheeze (33% vs. 11%, p = .010) and baseline resistance (Rrs 5 z‐score mean difference (MD) = 0.86, 95% CI 0.07–1.65, p = .025), but similar baseline spirometry to the group without a BDR (forced expiratory volume in 1 s [FEV 1 ] z‐score MD = −0.01, 95% CI −0.66 to 0.68, p > .999). Oscillometry was more feasible than spirometry (95% success rate vs. 85% (FEV 1 ), 69% (forced vital capacity) success rate, p < .001), however being born preterm did not affect test feasibility.

Conclusion

In the preterm population, oscillometry is a feasible and clinically useful supportive test to assess the airway response to inhaled salbutamol. Changes measured by oscillometry reflect related but distinct physiological changes to those measured by spirometry, and thus these tests should not be used interchangeably.

Subjects

MeSH terms (MEDLINE)

Bronchodilator AgentsAlbuterolInfant, NewbornHumansChildYoung AdultOscillometrySpirometryRespiratory Function TestsForced Expiratory VolumeLung

Author keywords

bronchodilator responsepretermrespiratory physiology

Substances

Bronchodilator AgentsAlbuterol

Authors and institutions

  • Wal-Yan Respiratory Research Centre, Telethon Kids Institute, Perth Children's Hospital, Nedlands, Australia.
  • Curtin School of Allied Health, Faculty of Health Sciences, Bentley, Australia.
  • Child and Adolescent Health Service, Perth Children's Hospital, Nedlands, Australia.

ORCID profiles: Tiffany K Bradshaw, Denby J Evans

Funding

  • National Health and Medical Research Council

Cite

APA

Smith, E. F., Bradshaw, T. K., Urs, R. C., Evans, D. J., Hemy, N. R., Hall, G. L., Wilson, A. C., & Simpson, S. J. (2023). Oscillometry and spirometry are not interchangeable when assessing the bronchodilator response in children and young adults born preterm. Pediatric Pulmonology, 58(11), 3122-3132. https://doi.org/10.1002/ppul.26632

Vancouver

Smith EF, Bradshaw TK, Urs RC, Evans DJ, Hemy NR, Hall GL, et al. Oscillometry and spirometry are not interchangeable when assessing the bronchodilator response in children and young adults born preterm. Pediatric Pulmonology. 2023;58(11):3122-3132. doi:10.1002/ppul.26632

BibTeX
@article{Smith2023,
  author = {Smith, Elizabeth F and Bradshaw, Tiffany K and Urs, Rhea C and Evans, Denby J and Hemy, Naomi R and Hall, Graham L and Wilson, Andrew C and Simpson, Shannon J},
  title = {Oscillometry and spirometry are not interchangeable when assessing the bronchodilator response in children and young adults born preterm},
  journal = {Pediatric Pulmonology},
  year = {2023},
  volume = {58},
  number = {11},
  pages = {3122--3132},
  doi = {10.1002/ppul.26632}
}
Start for free →