Respiratory physiology during NAVA ventilation in neonates born with a congenital diaphragmatic hernia: The “NAVA‐diaph” pilot study
Pediatric Pulmonology · 2023
DOI: 10.1002/ppul.26357 ↗At a glance
Journal article in Pediatric Pulmonology, 2023. Written by Lélia Dreyfus and 4 co-authors. Institution: Service de Néonatologie et Réanimation Néonatale, Hospices Civils de Lyon, Hôpital Femme Mère Enfant, Bron, France. Major MEDLINE topics: Hernias, Diaphragmatic, Congenital, Interactive Ventilatory Support. Cited 1 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Background
Neurally adjusted ventilatory assist (NAVA) is a ventilatory mode that delivers synchronized ventilation, proportional to the electrical activity of the diaphragm (EAdi). Although it has been proposed in infants with a congenital diaphragmatic hernia (CDH), the diaphragmatic defect and the surgical repair could alter the physiology of the diaphragm.
Aim
To evaluate, in a pilot study, the relationship between the respiratory drive (EAdi) and the respiratory effort in neonates with CDH during the postsurgical period under either NAVA ventilation or conventional ventilation (CV).
Methods
This prospective physiological study included eight neonates admitted to a neonatal intensive care unit with a diagnosis of CDH. EAdi, esophageal, gastric, and transdiaphragmatic pressure, as well as clinical parameters, were recorded during NAVA and CV (synchronized intermittent mandatory pressure ventilation) in the postsurgical period.
Results
EAdi was detectable and there was a correlation between the ΔEAdi (maximal − minimal values) and the transdiaphragmatic pressure ( r = 0.26, 95% confidence interval [CI] [0.222; 0.299]). There was no significant difference in terms of clinical or physiological parameters during NAVA compared to CV, including work of breathing.
Conclusion
Respiratory drive and effort were correlated in infants with CDH and therefore NAVA is a suitable proportional mode in this population. EAdi can also be used to monitor the diaphragm for individualized support.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Service de Néonatologie et Réanimation Néonatale, Hospices Civils de Lyon, Hôpital Femme Mère Enfant, Bron, France.
- Centre International de Recherche en infectiologie (CIRI), Team "Pathogénie des Staphylocoques", CNRS, UMR5308, ENS de Lyon, Inserm, U1111, Université Claude Bernard Lyon 1, Lyon, France.
- EA 419, Université Claude Bernard Lyon 1, Villeurbanne, France.
- Service de réanimation pédiatrique, Hospices Civils de Lyon, Hôpital Femme Mère Enfant, Bron, France.
- Unité APCSe (UP 2021, A101), Universités de Lyon, VetAgro Sup, Marcy l'Etoile, France.
ORCID profiles: Lélia Dreyfus, Florent Baudin
Cite
APA
Dreyfus, L., Butin, M., Plaisant, F., Claris, O., & Baudin, F. (2023). Respiratory physiology during NAVA ventilation in neonates born with a congenital diaphragmatic hernia: The “NAVA‐diaph” pilot study. Pediatric Pulmonology. https://doi.org/10.1002/ppul.26357
Vancouver
Dreyfus L, Butin M, Plaisant F, Claris O, Baudin F. Respiratory physiology during NAVA ventilation in neonates born with a congenital diaphragmatic hernia: The “NAVA‐diaph” pilot study. Pediatric Pulmonology. 2023. doi:10.1002/ppul.26357
BibTeX
@article{Dreyfus2023,
author = {Dreyfus, Lélia and Butin, Marine and Plaisant, Frank and Claris, Olivier and Baudin, Florent},
title = {Respiratory physiology during NAVA ventilation in neonates born with a congenital diaphragmatic hernia: The “NAVA‐diaph” pilot study},
journal = {Pediatric Pulmonology},
year = {2023},
doi = {10.1002/ppul.26357}
}
EUVIMED