EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Relationship between muscle thickness measured by ultrasound and physical functions: A 2‐year follow‐up study of allogeneic hematopoietic stem cell transplantation recipients

Kumiko Ito iD, Yuma Tada, Masayuki Suzuki, Nao Hashida, Yuji Kato, Takafumi Yokota, Jun Ishikawa, Hironari Tamiya

PM&R · 2024

DOI: 10.1002/pmrj.13083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PM&R, 2024. Verfasst von Kumiko Ito und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation, Osaka International Cancer Institute, Osaka, Japan. Hauptthemen laut MEDLINE: Hematopoietic Stem Cell Transplantation, Ultrasonography, Muscle Strength. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: the Osaka International Cancer Institute Fund for supporting collaborative Research, 2019.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Allogeneic hematopoietic stem cell transplantation (allo‐HSCT) is a potentially curative treatment for hematological malignancies. Several complications following allo‐HSCT, such as graft‐versus‐host disease, infection, and malnutrition, often cause physical dysfunction, and the assessment of physical function and evaluation of muscle mass are incompletely performed. Use of ultrasound (US) allows muscle mass measurement in patients with poor general conditions. In allo‐HSCT recipients, the correlation between physical function and muscle thickness, as measured by US, remains unclear.

Objective

To clarify whether muscle thickness measured by US correlated with physical function in allo‐HSCT recipients.

Design

A single‐center prospective cohort study.

Setting

Hospital. Patients Ninety‐two patients underwent allo‐HSCT at our hospital from April 2017 to March 2019.

Interventions

Not applicable. Main Outcome Measure(s) Biceps and quadriceps muscle thickness measured by US, grip strength, isometric muscle strength (elbow flexion and knee extension), and 6‐minute walking test (6MWT) before allo‐HSCT and on days 30, 90, 180, 1 year, and 2 years after allo‐HSCT. The implementation rates of these assessments were also investigated.

Results

Correlations were observed between biceps thickness and elbow flexion muscle strength/grip strength before allo‐HSCT, on days 30, 90, 180, 1 year, and 2 years after allo‐HSCT ( r = 0.71/0.74, 0.73/0.72, 0.70/0.79, 0.67/0.75, 0.72/0.75, and 0.85/0.79, respectively, all p < .001). At the same time points, quadriceps thickness moderately correlated with knee extensor strength ( r = 0.49, 0.50, 0.45, 0.64, 0.61, and 0.58, all p < .001). However, biceps and quadriceps thicknesses did not correlate with the 6MWT. The percentages of patients measured with US and 6MWT were 93.4% and 82.4% ( p = .01) on day 30 and 97.5% and 87.8% ( p = .02) on day 90, respectively.

Conclusions

US assessment may be a useful alternative method for estimating muscle strength in fragile allo‐HSCT recipients, particularly when physical function assessment is difficult to quantify.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hematopoietic Stem Cell TransplantationUltrasonographyMuscle StrengthHumansMaleFemaleProspective StudiesMiddle AgedAdultFollow-Up StudiesTransplantation, HomologousHand StrengthMuscle, SkeletalTime FactorsAgedQuadriceps Muscle

Autor:innen und Institutionen

  • Department of Rehabilitation, Osaka International Cancer Institute, Osaka, Japan.
  • Department of Hematology, Osaka International Cancer Institute, Osaka, Japan.
  • Swallowing Center, Osaka University Hospital, Osaka, Japan.
  • Department of Orthopedic Surgery, Osaka International Cancer Institute, Osaka, Japan.

ORCID-Profile: Kumiko Ito

Förderung

  • the Osaka International Cancer Institute Fund for supporting collaborative Research, 2019

Zitieren

APA

Ito, K., Tada, Y., Suzuki, M., Hashida, N., Kato, Y., Yokota, T., Ishikawa, J., & Tamiya, H. (2024). Relationship between muscle thickness measured by ultrasound and physical functions: A 2‐year follow‐up study of allogeneic hematopoietic stem cell transplantation recipients. PM&R. https://doi.org/10.1002/pmrj.13083

Vancouver

Ito K, Tada Y, Suzuki M, Hashida N, Kato Y, Yokota T, et al. Relationship between muscle thickness measured by ultrasound and physical functions: A 2‐year follow‐up study of allogeneic hematopoietic stem cell transplantation recipients. PM&R. 2024. doi:10.1002/pmrj.13083

BibTeX
@article{Ito2024,
  author = {Ito, Kumiko and Tada, Yuma and Suzuki, Masayuki and Hashida, Nao and Kato, Yuji and Yokota, Takafumi and Ishikawa, Jun and Tamiya, Hironari},
  title = {Relationship between muscle thickness measured by ultrasound and physical functions: A 2‐year follow‐up study of allogeneic hematopoietic stem cell transplantation recipients},
  journal = {PM&R},
  year = {2024},
  doi = {10.1002/pmrj.13083}
}
Kostenlos starten →