EUVIMEDEUVIMED entdecken
Crossref

Muscle measures from computed tomography, bioelectrical impedance, and ultrasound in hematopoietic cell transplantation patients

Rusha Bhandari, Kyuwan Lee, Xinyi Du, Sophia Albanese, Meagan Echevarria, Caitlyn Estrada, Alexander Flores, Aleksi Iukuridze, David Iukuridze, Janice Kim, Lanie Lindenfeld, Stephanie Rodarte und 3 weitere

Nutrition in Clinical Practice · 2025

DOI: 10.1002/ncp.11304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nutrition in Clinical Practice, 2025. Verfasst von Rusha Bhandari und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Population Sciences, City of Hope, Duarte, California, USA. Hauptthemen laut MEDLINE: Electric Impedance, Hematopoietic Stem Cell Transplantation, Tomography, X-Ray Computed, Quadriceps Muscle. Die Arbeit nennt 18 Literaturangaben. Gefördert von: NCI NIH HHS, This work was supported, in part, by grants from the NIH (K12CA001727 [Mortimer] and R01HL150069 [Saro H. Armenian]) and by the TREC Training Workshop R25CA203…, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Low muscle mass is associated with adverse outcomes following hematopoietic cell transplantation (HCT). Computed tomography (CT) is a gold standard approach to measuring skeletal muscle but is associated with radiation exposure and no longer routinely performed in all patients before HCT. Alternative methods are needed for early identification, intervention, and serial evaluation of low muscle mass after HCT. Optimal methods should be portable and readily accessible. We thus evaluated the correlation between quadriceps muscle ultrasound (US), whole‐body bioelectrical impedance analysis (BIA), and muscle CT in patients planned to undergo HCT.

Methods

This study included 71 consecutive patients ≥18 years who underwent first HCT between 2020 and 2024. Pearson correlation examined the relationship between skeletal muscle measurements of cross‐sectional area (CSA) from CT images at the third lumbar vertebra (L3), whole‐body skeletal muscle mass (SMM) from BIA, and CSA from quadriceps muscle US.

Results

Median age at evaluation was 52.6 years (range: 18.6–76.6). CT‐derived L3 skeletal muscle CSA positively correlated with quadriceps muscle US CSA ( r = 0.73; P < 0.0001) and BIA SMM ( r = 0.92; P < 0.0001). Quadriceps muscle US and BIA SMM were also positively correlated ( r = 0.74; P < 0.0001). Positive correlations were consistent across body mass index (BMI) and age categories.

Conclusions

Quadriceps muscle US and whole‐body BIA offer reliable alternatives to estimate skeletal muscle without radiation exposure. US is more readily available, allowing for detailed phenotypic evaluation of individual muscles and identification of muscle compromise that may occur following HCT. This can enable development and monitoring of tailored and targeted interventions to improve muscle health and HCT outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electric ImpedanceHematopoietic Stem Cell TransplantationTomography, X-Ray ComputedQuadriceps MuscleMuscle, SkeletalHumansMiddle AgedFemaleAdultMaleUltrasonographyAgedYoung AdultAdolescentBody Composition

Stichwörter der Autor:innen

adultbody compositionhematopoietic/stem cell transplantlife cycleresearch and diseases

Autor:innen und Institutionen

  • Department of Population Sciences, City of Hope, Duarte, California, USA.
  • Department of Pediatrics, City of Hope, Duarte, California, USA.
  • David Geffen School of Medicine at University of California Los Angeles, Los Angeles, California, USA.
  • Department of Radiology, City of Hope, Duarte, California, USA.

Förderung

  • NCI NIH HHS
  • This work was supported, in part, by grants from the NIH (K12CA001727 [Mortimer] and R01HL150069 [Saro H. Armenian]) and by the TREC Training Workshop R25CA203…
  • National Institutes of Health

Zitieren

APA

Bhandari, R., Lee, K., Du, X., Albanese, S., Echevarria, M., Estrada, C., Flores, A., Iukuridze, A., Iukuridze, D., Kim, J., Lindenfeld, L., Rodarte, S., Salce, N., Wong, F. L., & Armenian, S. H. (2025). Muscle measures from computed tomography, bioelectrical impedance, and ultrasound in hematopoietic cell transplantation patients. Nutrition in Clinical Practice. https://doi.org/10.1002/ncp.11304

Vancouver

Bhandari R, Lee K, Du X, Albanese S, Echevarria M, Estrada C, et al. Muscle measures from computed tomography, bioelectrical impedance, and ultrasound in hematopoietic cell transplantation patients. Nutrition in Clinical Practice. 2025. doi:10.1002/ncp.11304

BibTeX
@article{Bhandari2025,
  author = {Bhandari, Rusha and Lee, Kyuwan and Du, Xinyi and Albanese, Sophia and Echevarria, Meagan and Estrada, Caitlyn and Flores, Alexander and Iukuridze, Aleksi and Iukuridze, David and Kim, Janice and Lindenfeld, Lanie and Rodarte, Stephanie and Salce, Nathan and Wong, F Lennie and Armenian, Saro H},
  title = {Muscle measures from computed tomography, bioelectrical impedance, and ultrasound in hematopoietic cell transplantation patients},
  journal = {Nutrition in Clinical Practice},
  year = {2025},
  doi = {10.1002/ncp.11304}
}
Kostenlos starten →